IBM 88643RU Service Guide - Page 121
diagnostics
UPC - 000435958211
View all IBM 88643RU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
v Check the power supplies, see Power-supply LEDs. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a trained service technician. Lit light path diagnostics LED with the system-error or system-information LED also lit Description Action CPU A microprocessor has failed, is missing, or has been improperly installed. Note: Make sure that the microprocessors are installed in the correct sequence; see "Removing and installing a microprocessor" on page 55. 1. Check the BMC log or the system-error log to determine the reason for the lit LED. 2. Find the failing, missing, or mismatched microprocessor by checking the LEDs on the microprocessor tray. 3. Reseat the following components: a. (Trained service technician only) Failing microprocessor b. Microprocessor tray 4. Replace the following components one at a time, in the order shown, restarting the server each time. a. (Trained service technician only) Failing microprocessor b. (Trained service technician only) Microprocessor tray VRM A dc-dc regulator has failed or is missing. 1. Check the BMC log or the system-error log to determine the reason for the lit LED (for a VRM). 2. Find the failing or missing VRM by checking the LEDs on the microprocessor tray. 3. Install any missing VRMs. 4. Reseat the following components: a. Failing VRM b. (Trained service technician only) Microprocessor associated with the VRM c. Microprocessor tray 5. Replace the following components one at a time, in the order shown, restarting the server each time. a. Failing VRM b. (Trained service technician only) Microprocessor associated with the VRM c. (Trained service technician only) Microprocessor tray LOG Information is present in the BMC 1. The system-error log is 75% full; save the log if log and system-error log. One or necessary and clear it (see Error Logs at both logs may be full or close to full. "Configuration/Setup Utility menu choices" on page 15). 2. Check the log for possible errors (see "Error logs" on page 70). Chapter 5. Diagnostics 105