Page 98 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a trained service technician. Error code Description Action 00180200 No more I/O space is available for a PCI adapter. 1. If the error code indicates a particular PCI slot or device, remove that device. 2. If the error continues, reseat the following components: a. Each adapter b. (Trained service technician only) PCI board 3. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time. 00180300 No more memory (above 1 MB for a PCI adapter). 1. If the error code indicates a particular PCI slot or device, remove that device. 2. Reseat the following components: a. Each adapter b. (Trained service technician only) PCI board 3. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time. 00180400 No more memory (below 1 MB for a PCI adapter). 1. Reseat the following components: a. Each adapter b. (Trained service technician only) PCI board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 00180500 PCI option ROM checksum error. 1. Remove the failing PCI adapter. 2. Reseat the following components: a. Each adapter b. (Trained service technician only) PCI board 3. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time. 00180600 PCI built-in self-test failure. 1. If the error code indicates a particular PCI slot or device, remove that device. Note: Slot 0 indicates the I/O board. 2. Reseat the following components: a. Each adapter b. (Trained service technician only, if the specified board is a FRU). The board indicated in the error code. (See Chapter 3, "Parts listing, Type 8864," on page 23, to determine CRU or FRU status.) 3. Replace the components listed in step 2 one at a time, in the order shown above, restarting the server each time. 82 IBM System x3850 Type 8864: Problem Determination and Service Guide