IBM HS22 User Guide - Page 22

Predictive Failure Analysis PFA, Size Type 7870 and Type 1936 - blade memory

Page 22 highlights

The following table is a summary of the features and specifications of the blade server. Table 1. Features and specifications Microprocessor: Supports up to two Predictive Failure Analysis (PFA) Drives: Supports up to two hot-swap, multi-core Intel Xeon microprocessors. alerts: small form factor (SFF) Serial Attached Note: Use the Setup utility to v Microprocessors SCSI (SAS) or Serial ATA (SATA) determine the type and speed of the v Memory storage drives microprocessors in the blade server. v Storage drives Size (Type 7870 and Type 1936): Memory: Electrical input: 12 V dc v Height: 24.5 cm (9.7 inches) (6U) v 12 dual inline memory module v Depth: 44.6 cm (17.6 inches) (DIMM) connectors v Type: Very Low Profile (VLP) Environment: v Air temperature: v Width: 2.9 cm (1.14 inches) v Maximum weight: 4.8 kg (10 lb) double-data rate (DDR3) DRAM. Supports 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB DIMMs with up to 192 GB of total memory on the system board - Blade server on: 10°C to 35°C (50°F to 95°F). Altitude: 0 m to 914.4 m (0 ft to 3000 ft) - Blade server on: 10°C to 32°C (50°F to 89.6°F). Altitude: 914.4 Size (Type 1911): v Height: 24.5 cm (9.7 in) v Depth: 44.6 cm (17.6 in) v Width: 14.5 cm (5.71 in) m to 2133.6 m (3000 ft to 7000 v Maximum weight: 8.15 kg (40.02 lb) Integrated functions: v Horizontal-compact-form-factor ft) - Blade server off: 10°C to 43°C NEBS Environment (CFFh) expansion card interface v Vertical-combination-I/O (CIOv) (50°F to 109.4°F). Altitude: 914.4 v Air temperature: m to 2133.6 m (3000 ft to 7000 - Blade server on: 5°C to 40°C (41°F expansion card interface v Local service processor: Integrated Management Module (IMM) with Intelligent Platform Management Interface (IPMI) firmware ft) - Blade server shipping: -40°C to 60°C (-40°F to 140°F) v Humidity: - Blade server on: 8% to 80% to 104°F). Altitude: -60 m to 1800 m (-197 ft to 6000 ft) - Blade server on: 5°C to 30°C (41°F to 86°F). Altitude: 1800 m to 4000 m (6000 ft to 13000 ft) v Integrated Matrox G200eV video controller - Blade server off: 8% to 80% - Blade server off: -5°C to 55°C - Blade server storage: 5% to 80% (23°F to 131°F). Altitude: -60 m to v LSI 1064E SAS controller v Broadcom BCM5709S dual-port - Blade server shipment: 5% to 100% 1800 m (-197 ft to 6000 ft) - Blade server off: -5°C to 45°C Gigabit Ethernet controller v Particulate contamination: v Integrated keyboard/video/mouse (cKVM) controller through IMM v Light path diagnostics v RS-485 interface for communication with the management module v Automatic server restart (ASR) v USB 2.0 for communication with cKVM and removable media drives (an external USB port is not supported) v Serial over LAN (SOL) Attention: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see "Particulate contamination" on page 85. (23°F to 113°F). Altitude: 1800 m to 4000 m (6000 ft to 13000 ft) - Blade server storage: -40°C to 60°C (-40°F to 140°F) v Humidity: 8% to 85% v Particulate contamination: Attention: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information v Redundant buses for about the limits for particulates and communication with keyboard, gases, see "Particulate mouse, and removable media contamination" on page 85. drives 8 BladeCenter HS22 Type 7870, 1936, and 1911: Installation and User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

The following table is a summary of the features and specifications of the blade
server.
Table 1. Features and specifications
Microprocessor:
Supports up to two
multi-core Intel Xeon microprocessors.
Note:
Use the Setup utility to
determine the type and speed of the
microprocessors in the blade server.
Memory:
v
12 dual inline memory module
(DIMM) connectors
v
Type: Very Low Profile (VLP)
double-data rate (DDR3) DRAM.
Supports 1 GB, 2 GB, 4 GB, 8 GB,
and 16 GB DIMMs with up to 192
GB of total memory on the system
board
Integrated functions:
v
Horizontal-compact-form-factor
(CFFh) expansion card interface
v
Vertical-combination-I/O (CIOv)
expansion card interface
v
Local service processor: Integrated
Management Module (IMM) with
Intelligent Platform Management
Interface (IPMI) firmware
v
Integrated Matrox G200eV video
controller
v
LSI 1064E SAS controller
v
Broadcom BCM5709S dual-port
Gigabit Ethernet controller
v
Integrated keyboard/video/mouse
(cKVM) controller through IMM
v
Light path diagnostics
v
RS-485 interface for communication
with the management module
v
Automatic server restart (ASR)
v
USB 2.0 for communication with
cKVM and removable media drives
(an external USB port is not
supported)
v
Serial over LAN (SOL)
v
Redundant buses for
communication with keyboard,
mouse, and removable media
drives
Predictive Failure Analysis (PFA)
alerts:
v
Microprocessors
v
Memory
v
Storage drives
Electrical input:
12 V dc
Environment:
v
Air temperature:
Blade server on: 10°C to 35°C
(50°F to 95°F). Altitude: 0 m to
914.4 m (0 ft to 3000 ft)
Blade server on: 10°C to 32°C
(50°F to 89.6°F). Altitude: 914.4
m to 2133.6 m (3000 ft to 7000
ft)
Blade server off: 10°C to 43°C
(50°F to 109.4°F). Altitude: 914.4
m to 2133.6 m (3000 ft to 7000
ft)
Blade server shipping: -40°C to
60°C (-40°F to 140°F)
v
Humidity:
Blade server on: 8% to 80%
Blade server off: 8% to 80%
Blade server storage: 5% to 80%
Blade server shipment: 5% to
100%
v
Particulate contamination:
Attention:
Airborne particulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
“Particulate contamination” on
page 85.
Drives:
Supports up to two hot-swap,
small form factor (SFF) Serial Attached
SCSI (SAS) or Serial ATA(SATA)
storage drives
Size (Type 7870 and Type 1936):
v
Height: 24.5 cm (9.7 inches) (6U)
v
Depth: 44.6 cm (17.6 inches)
v
Width: 2.9 cm (1.14 inches)
v
Maximum weight: 4.8 kg (10 lb)
Size (Type 1911):
v
Height: 24.5 cm (9.7 in)
v
Depth: 44.6 cm (17.6 in)
v
Width: 14.5 cm (5.71 in)
v
Maximum weight: 8.15 kg (40.02 lb)
NEBS Environment
v
Air temperature:
Blade server on: 5°C to 40°C (41°F
to 104°F). Altitude: -60 m to 1800
m (-197 ft to 6000 ft)
Blade server on: 5°C to 30°C (41°F
to 86°F). Altitude: 1800 m to 4000
m (6000 ft to 13000 ft)
Blade server off: -5°C to 55°C
(23°F to 131°F). Altitude: -60 m to
1800 m (-197 ft to 6000 ft)
Blade server off: -5°C to 45°C
(23°F to 113°F). Altitude: 1800 m
to 4000 m (6000 ft to 13000 ft)
Blade server storage: -40°C to
60°C (-40°F to 140°F)
v
Humidity: 8% to 85%
v
Particulate contamination:
Attention:
Airborne particulates
and reactive gases acting alone or in
combination with other
environmental factors such as
humidity or temperature might pose
a risk to the server. For information
about the limits for particulates and
gases, see “Particulate
contamination” on page 85.
8