Icom ID-5100A Full Instruction Manual - Page 236

Scan items, Pause Timer, Resume Timer, Temporary Skip Timer, Program Skip, Bank Link

Page 236 highlights

Previous view 12 MENU SCREEN Scan items Pause Timer (Default: 10sec) Scan > Pause Timer Select the scan Pause time. When receiving a signal, the scan pauses for the scan Pause Timer time. • 2sec to 20sec : When a signal is received, the scan pauses for 2 to 20 seconds (set in 2 second steps). • HOLD : The scan pauses on a received signal until the signal disappears. Resume Timer (Default: 2sec) Scan > Resume Timer Select the scan Resume Timer time. When a received signal disappears, the scan resumes according to the scan Resume Timer setting. • 0sec: The scan resumes immediately after the signal disappears. • 1sec to 5sec: T he scan resumes 1 to 5 seconds after the signal disappears. • HOLD: The scan remains paused for the Pause Timer setting, even if the signal disappears. NOTE: Rotate [DIAL] to resume the scan. The Resume Timer must be set shorter than the Pause Timer, otherwise this timer does not work properly. Bank Link (Default: A:✔ - Z:✔) Scan > Bank Link Select banks to be scanned during a Bank Link Scan. The Bank Link function scans all channels in the selected banks. Touch a desired bank, A to Z to turn the link ON or OFF. Program Scan Edge Scan > Program Scan Edge You can delete, copy or edit the lower and higher frequencies for programmed scans. A total of up to 25 frequency ranges (00-24) can be programmed. You can set the scan name, tuning step and the receive mode for each scan edge. The default setting is differ, depending on the transceiver's version. See page 4-12 for Entering scan edges. Temporary Skip Timer (Default: 5min) Scan > Temporary Skip Timer Set the Temporary Skip Timer to 5, 10 or 15 minutes. When the time is set, the unwanted frequencies are skipped for this set period during a scan. This timer activates for the VFO scan, Memory scan and DR scan. Program Skip (Default: ON) Scan > Program Skip Turn the Program Skip Scan function ON or OFF for a VFO mode scan. This function enables the transceiver to skip the unwanted frequencies or channels that inconveniently stop scanning. Set the unwanted frequencies or channels to "PSKIP" in the Memory Channel screen. • OFF: The transceiver scans all frequencies. • ON: The transceiver does not scan frequencies set as "PSKIP" frequencies. 12-14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352

12
MENU SCREEN
12-14
Scan items
Pause Timer
(Default: 10sec)
Scan > Pause Timer
Select the scan Pause time. When receiving a signal,
the scan pauses for the scan Pause Timer time.
2sec to 20sec : When a signal is received, the scan
pauses for 2 to 20 seconds (set in 2
second steps).
HOLD
: The scan pauses on a received signal
until the signal disappears.
Resume Timer
(Default: 2sec)
Scan > Resume Timer
Select the scan Resume Timer time.
When a received signal disappears, the scan resumes
according to the scan Resume Timer setting.
• 0sec:
The scan resumes immediately after
the signal disappears.
• 1sec to 5sec:
The scan resumes 1 to 5 seconds after
the signal disappears.
• HOLD:
The scan remains paused for the Pause
Timer setting, even if the signal disap-
pears.
NOTE:
Rotate [DIAL] to resume the scan.
The Resume Timer must be set shorter than the
Pause Timer, otherwise this timer does not work
properly.
Temporary Skip Timer
(Default: 5min)
Scan > Temporary Skip Timer
Set the Temporary Skip Timer to 5, 10 or 15 minutes.
When the time is set, the unwanted frequencies are
skipped for this set period during a scan.
This timer activates for the VFO scan, Memory scan
and DR scan.
Program Skip
(Default: ON)
Scan > Program Skip
Turn the Program Skip Scan function ON or OFF for a
VFO mode scan.
This function enables the transceiver to skip the un-
wanted frequencies or channels that inconveniently
stop scanning.
Set the unwanted frequencies or channels to “PSKIP”
in the Memory Channel screen.
• OFF:
The transceiver scans all frequencies.
• ON:
The transceiver does not scan frequencies set
as “PSKIP” frequencies.
Bank Link
(Default: A:
– Z:
)
Scan > Bank Link
Select banks to be scanned during a Bank Link Scan.
The Bank Link function scans all channels in the se-
lected banks.
Touch a desired bank, A to Z to turn the link ON or
OFF.
Program Scan Edge
Scan > Program Scan Edge
You can delete, copy or edit the lower and higher fre-
quencies for programmed scans.
A total of up to 25 frequency ranges (00–24) can be
programmed.
You can set the scan name, tuning step and the receive
mode for each scan edge.
The default setting is differ, depending on the trans-
ceiver’s version.
See page 4-12 for Entering scan edges.