2 SETTING UP ThE TRANSCEIvERS Unicast mode operation Connection Port Settings > EXT I/O (EXT) Bridge Connection Settings > Bridge Connection In the Unicast mode, you can call the designated radio, through a communication port. This instruction is the example of the setting to communicate between the transceivers (A1 and B1) in the simplex mode: Icom transceiver (SU) Icom Transceiver IC-F5060 [EXT1] Area A VE-PG4 IP Network Area B VE-PG4 Icom transceiver IC-F5060 [EXT1] Icom transceiver (SU) A1 192.168.0.1 192.168.0.2 B1 ■ Registering the transceiver to the RoIP Gateway 1 Open the EXT I/O (EXT) screen. (Connection Port Settings > EXT I/O (EXT)) 2 In [EXT I/O Port Mode], confirm "Connected Unit" for EXT I/O1 (EXT1) is set to "Transceiver." Confirm 3 Confirm the EXT I/O Port is set to "EXT I/O 1 (EXT1)," Select "IC-F5060/F6060" in Transceiver Model, and then click . L When connecting another transceiver model, select appropriate model name. q Confirm w Select e Click (☞ Continued on the next page) 2-10