Icom VE-PG4 Installation Guide ver.1.34 - Page 36

Custom Bridge Connection, and the IP address of the destination Example: VE-PG4 in Area B

Page 36 highlights

2 SETTING UP ThE TRANSCEIvERS Unicast mode operation ■ Registering the transceiver to the RoIP Gateway 4 Open the Bridge Connection screen. (Bridge Connection Settings > Bridge Connection) 5 In [Bridge Connection], set the connection Source (Example: EXT1), the Bridge Connection Destination (Custom Bridge Connection), and the IP address of the destination (Example: vE-PG4 in Area B (192.168.0.2)), then click . q Confirm w Enter e Click • The confirmation dialogs are displayed. Click twice to apply them. L When the bridge connection is set, the Connection Port setting is deleted from the "Destination Settings." (Destination settings > Destination Settings) 6 In [AMBE+2 vocoder Assignment], set the voice Protocol and AMBE+2 vocoder Assignment, and then click . q Select w Click L At default, all of the 4 Internal AMBE+2 vocoders are assigned to the digital transceivers. Disable one of the internal AMBE+2 vocoder to assign it to the EXT1 port. L If you need an additional AMBE+2 vocoder, an optional CT-24 digital voice converter is required. (☞ Continued on the next page) 2-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

2
SETTING UP THE TRANSCEIVERS
2-11
Unicast mode operation
Registering the transceiver to the RoIP Gateway
(
Continued on the next page)
4
Open the Bridge Connection screen.
(Bridge Connection Settings > Bridge Connection)
5
In [Bridge Connection], set the connection Source (Example: EXT1), the Bridge Connection Destination
(Custom Bridge Connection), and the IP address of the destination (Example: VE-PG4 in Area B
(192.168.0.2)), then click <Apply>.
w
Enter
e
Click
q
Confirm
The confirmation dialogs are displayed. Click <OK> twice to apply them.
L
When the bridge connection is set, the Connection Port setting is deleted from the “Destination Settings.”
(Destination settings > Destination Settings)
6
In [AMBE+2 Vocoder Assignment], set the Voice Protocol and AMBE+2 Vocoder Assignment, and then
click <Apply>.
q
Select
w
Click
L
At default, all of the 4 Internal AMBE+2 vocoders are assigned to the digital transceivers. Disable one of the
internal AMBE+2 vocoder to assign it to the EXT1 port.
L
If you need an additional AMBE+2 vocoder, an optional CT-24
DIGITAL
VOICE
CONVERTER
is required.