Intel SR2600UR Service Guide - Page 114
Filling Empty Server System Bays (Intel® Server System SR2600UR only
UPC - 735858206778
View all Intel SR2600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
8. Connect the other end of the data cables to the two hard disk drives (see letter "D" in Figure 85). B D C A Figure 85. Installing Power and Data Cables AF003038 Filling Empty Server System Bays (Intel® Server System SR2600UR only) In the Intel® Server System SR2600UR, you must install either a filler panel, drive blank, or empty drive carrier into an empty drive bay. To access the drive bays, remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel" on page 46. With the bezel removed, install the appropriate filler panel(s), drive blank, or empty hard drive bay(s) as follows: • If you do not have an optical drive installed in the slimline bay, install the slimline filler panel (see letter "A" in Figure 86). • If you have a sixth hard drive installed in the flex bay (that is, empty slot above drive bay 4), install the sixth hard drive filler panel above the sixth drive bay (see letter "B" in Figure 86). • If you do not have either a sixth hard drive, tape drive, or 2.5 inch fixed hard drives installed in the flex bay, install the default filler panel into the flex bay (that is, empty slot above drive bay 4) (see letter "C" in Figure 86). 94 Intel® Server System SR2600UR/SR2625UR Service Guide