Installing the Large Air Baffle on, Replacing a Fan Module
![]() |
UPC - 735858206778
View all Intel SR2600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
8. Lift the module from the server system (see letter "B" in Figure 116). A B A AF002982 Figure 116. Removing the Power Distribution Module 9. Set the replacement power supply distribution module into the server system and screw the module into place. 10. Install the hot-swap power supply/supplies. For instructions, see "Replacing the Power Supply" on page 120. 11. Connect all power cables to the server board. 12. Install the fan module assembly. For instructions, see "Replacing a Fan Module" on page 127. 13. Install the large air baffle. For instructions, see "Installing the Large Air Baffle" on page 70. 14. Install the processor air duct. For instructions, see "Installing the Processor Air Duct" on page 57. 15. Install the PCI riser assembly. For instructions, see "Installing the PCI Riser Assembly" on page 51. Intel® Server System SR2600UR/SR2625UR Service Guide 123
![](/manual_guide/products/intel-sr2600ur-service-guide-1ac9b07/143.png)