Intel SR2600UR Service Guide - Page 147
Replacing a Fan Module, Replacing a Redundant Fan Module
![]() |
UPC - 735858206778
View all Intel SR2600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
7. Connect the two cables to the USB and control panel connectors on the back side of the backplane as shown (see letter "B" in Figure 121). Backplane B A AF003016 Figure 121. Installing Control Panel Module into the Server System Replacing a Fan Module See the following sections: • "Replacing a Redundant Fan Module" on page 127 for instructions to replace a redundant fan module • "Replacing a Fixed Fan Module" on page 130 for instructions to replace a fixed fan module Replacing a Redundant Fan Module To replace a redundant fan module, follow these steps: 1. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly" on page 50. 2. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct" on page 56. 3. Remove the large air baffle. For instructions, see "Removing the Large Air Baffle" on page 70. 4. Remove the fan baffle. For instructions, see "Removing the Fan Baffle" on page 67. 5. Remove the bridge board. For instructions, see step 5 in "Removing the Midplane Board" on page 102. 6. Disconnect the fan cables from the midplane. Intel® Server System SR2600UR/SR2625UR Service Guide 127
![](/manual_guide/products/intel-sr2600ur-service-guide-1ac9b07/147.png)