Intel SR2600UR Service Guide - Page 87

Removing and Installing the Fan Baffle, Removing the Fan Baffle

Page 87 highlights

Figure 50. Installing the Small Air Baffle AF002959 Removing and Installing the Fan Baffle Some installation processes require that you remove the fan baffle that is placed between fans 3 and 5 and the backplane, near the front of your server. The following sections describe how to remove and then install the fan baffle. Use the instructions in these sections only when it is indicated as necessary for a component installation process. Always operate your server system with the fan baffle in place. The fan baffle is required for proper airflow within the server system. Removing the Fan Baffle To remove the fan baffle, follow these steps: 1. Remove the hook (on the front of the baffle) from the hole in the backplane board (see letter "A" in Figure 51 - the arrow is pointing to the hook in the baffle). 2. Slide the baffle out in the direction shown (see letter "B" in Figure 51). 3. Pull up on it (see letter "C" in Figure 51). Intel® Server System SR2600UR/SR2625UR Service Guide 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234

Intel
®
Server System SR2600UR/SR2625UR Service Guide
67
Figure 50. Installing the Small Air Baffle
Removing and Installing the Fan Baffle
Some installation processes require that you remove the fan baffle that is placed between
fans 3 and 5 and the backplane, near the front of your server. The following sections
describe how to remove and then install the fan baffle. Use the instructions in these
sections only when it is indicated as necessary for a component installation process.
Always operate your server system with the fan baffle in place. The fan baffle is required
for proper airflow within the server system.
Removing the Fan Baffle
To remove the fan baffle, follow these steps:
1.
Remove the hook (on the front of the baffle) from the hole in the backplane board
(see letter “A” in
Figure 51
- the arrow is pointing to the hook in the baffle).
2.
Slide the baffle out in the direction shown (see letter “B” in
Figure 51
).
3.
Pull up on it (see letter “C” in
Figure 51
).
AF002959