Intel SR2600UR Service Guide - Page 34
Intel® Light-Guided Diagnostics,
![]() |
UPC - 735858206778
View all Intel SR2600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Intel® Light-Guided Diagnostics The server system contains the following diagnostic LEDs, each providing the following functions: • The System Status LED on the front and back panels (see Figure 5 and Figure 8) shows the overall health of the system (green, blinking green, blinking amber, amber, off) . • The System Identification LED on the front and back panel (see Figure 5 and Figure 8) helps identify the server from among several servers. The ID LED is off by default, and blue when activated by button or software. • DIMM Fault LEDs on the server board (see Figure 5) help identify failed and failing DIMM slots. The DIMM fault LEDs turn on (amber) if there is a DIMM fault. • POST Code Diagnostic LEDs on the server board (see Figure 5) change color or state (off, green, red, amber) according to the POST sequence. • The 5V-STBY LED on the server board (see Figure 5) is illuminated (green) when AC power is applied. • Fan Fault LEDs on the passive midplane (in the passive system - see Figure 6) or active midplane (in the active system - see Figure 7) help identify failed and failing fans. The fan fault LEDs turn on (amber) if there is a fan fault. 14 Intel® Server System SR2600UR/SR2625UR Service Guide
![](/manual_guide/products/intel-sr2600ur-service-guide-1ac9b07/34.png)