Intel SR2600UR Service Guide - Page 97

Installing or Removing a Slimline Optical Drive or Internal USB Floppy (Intel® Server System

Page 97 highlights

4. Do one of the following: a. To install the replacement drive, see "Installing a SAS or SATA Hot-swap Hard Disk Drive" on page 71. b. If you are not installing a drive, place the plastic retention device into the drive carrier and secure the device by inserting the four screws you removed from the hard drive into the screw locations on the carrier. Note: To maintain proper system cooling, all hard drive carriers must be installed in the server system and populated with either a drive or a drive blank. 5. With the black lever held in the fully open position, slide the drive carrier into the server system and push all the way until it clicks. 6. Close the lever to lock the drive assembly into place. Installing or Removing a Slimline Optical Drive or Internal USB Floppy (Intel® Server System SR2600UR only) Cautions: The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. To maintain proper system cooling, a filler blank must be installed if you do not install a device at this location. Note: The Intel® Server System SR2600UR also supports the installation of a USB floppy in place of the slimline SATA optical device. Intel® Server System SR2600UR/SR2625UR Service Guide 77

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234

Intel
®
Server System SR2600UR/SR2625UR Service Guide
77
4.
Do one of the following:
a.
To install the replacement drive, see
“Installing a SAS or SATA Hot-swap Hard
Disk Drive” on page 71
.
b.
If you are not installing a drive, place the plastic retention device into the drive
carrier and secure the device by inserting the four screws you removed from the
hard drive into the screw locations on the carrier.
Note:
To maintain proper system cooling, all hard drive carriers must be installed in the server
system and populated with either a drive or a drive blank.
5.
With the black lever held in the fully open position, slide the drive carrier into the
server system and push all the way until it clicks.
6.
Close the lever to lock the drive assembly into place.
Installing or Removing a Slimline Optical Drive or
Internal USB Floppy (Intel
®
Server System SR2600UR
only)
Cautions:
The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
To maintain proper system cooling, a filler blank must be installed if you do not install a
device at this location.
Note:
The Intel
®
Server System SR2600UR also supports the installation of a USB floppy in
place of the slimline SATA optical device.