Intel SR2600UR Service Guide - Page 154
Replacing a Fixed Fan
![]() |
UPC - 735858206778
View all Intel SR2600UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 154 highlights
Note: Fan locations 1, 2, 3, and 4 use 80-mm fans. Fan locations 5 and 6 use 60-mm fans. 3. With the fan oriented correctly, insert the fan into the fan module, engaging the connector on the fan into the matching connector on the fan module (see Figure 127). 6 LX 5 4 3 2 1 Figure 127. Installing a Fan into the Redundant Fan Module Replacing a Fixed Fan Caution: The system fans are NOT hot-swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. Note: The fans that are integrated into the power supply cannot be replaced separately. If one of the fans in the power supply fails, the power supply must be replaced. The system fans at the front of the server system can be individually replaced if one of them fails. To replace a fan, follow these steps: 134 Intel® Server System SR2600UR/SR2625UR Service Guide