Sanyo 26KHS72R Installation Instructions - Page 14
Models, CH2672R, CH3072R, CH3672R, CH4272R, Tubing Data
![]() |
View all Sanyo 26KHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
07-115 SSHP_II 5/7/07 3:59 PM Page 14 Table 1-10 Tubing Data for Models Tubing Data Models C(H)2672R C(H)3072R C(H)3672R Tubing size outer diameter Liquid tube Gas tube in. (mm) in. (mm) 3/8 (9.52) 5/8 (15.88) 3/8 (9.52) 5/8 (15.88) Limit of tubing length (ft.) 165 165 Outdoor unit is placed Limit of elevation higher (ft.) 100 100 difference between Outdoor unit is placed the 2 units lower (ft.) 50 50 Max. allowable tubing length at shipment (ft.) Required additional refrigerant *1 (oz./ft.) Refrigerant charged at shipment (lbs.) 10 - 100 a) 0.43 4.2 10 - 100 b) 0.43 6.2 No additional charge of compressor oil is necessary. *1 If total tubing length becomes 100 to 165 ft., charge additional refrigerant by 0.43 oz./ft. C(H)4272R 3/8 (9.52) 5/8 (15.88) 165 100 50 10 - 100 b) 0.43 7.9 Table 1-11 List of Connection Tube Sizes Main tubing (L) Type capacity of indoor units Gas tube Liquid tube Amount of additional charge per 1 ft. 26 - 42 ø5/8" ø3/8" 0.43 oz. 14