Sanyo 26KHS72R Installation Instructions - Page 73
Mi, eration Alarm Indicator, Alarm, e of Trou, le 7-1
![]() |
View all Sanyo 26KHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
07-115 SSHP_II 5/7/07 4:00 PM Page 73 7-11. Misoperation Alarm Indicators Alarm indicator lamps on the indoor unit indicate the error cause if the air conditioner fails to operate upon being switched on. The possible alarm indications are given in Table 7-1. Fig. 7-12 shows the location of the alarm lamps on the indoor unit. (See Table 7-1 and Fig. 7-12.) Table 7-1 (OPERATION lamp) Alarm (TIMER lamp) (STANDBY lamp) * S.C.: Serial communications Cause of Trouble S.C. errors* between the indoor unit's controller (PCB) and the remote controller. Compressor protector is working. S.C. errors between indoor and outdoor units. Indoor or outdoor thermistor is malfunctioning. Outdoor unit protector is working. Indoor unit protector is working. TEST RUN switch on the operation controller is in ON state. RC (WL) OPERATION TIMER lamp lamp STANDBY lamp Remote control receiver Fig. 7-12 NOTE Stick the alarm message label accompanying the wireless remote controller on the electrical component box to indicate the cause of trouble for future reference. 73