Sanyo 26KHS72R Installation Instructions - Page 41

Arrangement for Left and Left-rear Tubing.

Page 41 highlights

07-115 SSHP_II 5/7/07 4:00 PM Page 41 3-14. Preparing the Indoor Side Tubing KH(S)2672R Arrangement of tubing by directions (a) Right tubing The corner of the right frame needs to be cut by a hacksaw or the like. (Fig. 3-46) (b) Right-rear or left-rear tubing In this case, the corner of the frame need not be cut. To mount the indoor unit on the rear panel: (a) Hang the 3 mounting slots of the unit on the upper tabs of the rear panel. (Fig. 3-47) KH(S)3072R, KH(S)3672R Tubing can be extended in 4 directions as shown in Fig. 3-54. Arrangement for Right-rear Tubing (a) Remove the 2 screws and slide out the side cover. (Fig. 3-48) (b) Extend the gas tube from the outdoor side and connect it directly to the mating tube inside the indoor unit. Use a flare nut. (Fig. 3-49) Arrangement for Right Tubing (a) Remove the 2 screws and take off the side cover. (Fig. 3-48) (b) Cut out the L-shaped tubing outlet using a hacksaw. (Fig. 3-50) (c) Using the L-shaped tube (field supply), connect tubing between the indoor and outdoor units. (Fig. 3-52) Arrangement for Left and Left-rear Tubing. (a) Remove the 4 screws (2 on each side) and take off both left and right side cover. (Fig. 3-51) (b) Remove 4 screws to remove the bottom cover. (c) Using the L-shaped tube (field supply), connect tubing as in Fig. 3-53. Frame Right tubing outlet Fig. 3-46 Mounting slot Tab K Fig. 3-47 Tubing from the outdoor unit Fig. 3-48 Fig. 3-49 Hacksaw Fig. 3-50 Indoor unit Left side cover Bottom cover Fig. 3-51 Right side cover L-shaped tube L-shaped tube Fig. 3-52 41 Fig. 3-53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111

41
K
3-14.
Preparing the Indoor Side Tubing
Arrangement of tubing by directions
(a)
Right tubing
The corner of the right frame needs to be cut by
a hacksaw or the like. (Fig. 3-46)
(b)
Right-rear or left-rear tubing
In this case, the corner of the frame need not be
cut.
To mount the indoor unit on the rear panel:
(a)
Hang the 3 mounting slots of the unit on the
upper tabs of the rear panel. (Fig. 3-47)
Tubing can be extended in 4 directions as shown in
Fig. 3-54.
Arrangement for Right-rear Tubing
(a)
Remove the 2 screws and slide out the side
cover. (Fig. 3-48)
(b)
Extend the gas tube from the outdoor side and
connect it directly to the mating tube inside the
indoor unit. Use a flare nut. (Fig. 3-49)
Arrangement for Right Tubing
(a)
Remove the 2 screws and take off the side cover.
(Fig. 3-48)
(b)
Cut out the L-shaped tubing outlet using a
hacksaw. (Fig. 3-50)
(c)
Using the L-shaped tube (field supply),
connect tubing between the indoor and
outdoor units. (Fig. 3-52)
Arrangement for Left and Left-rear Tubing.
(a)
Remove the 4 screws (2 on each side) and take
off both left and right side cover.
(Fig. 3-51)
(b)
Remove 4 screws to remove the bottom cover.
(c)
Using the L-shaped tube (field supply), connect
tubing as in Fig. 3-53.
KH(S)2672R
Frame
Right tubing
outlet
Fig. 3-46
Tab
Mounting slot
Fig. 3-47
KH(S)3072R, KH(S)3672R
Fig. 3-48
Tubing
from the
outdoor
unit
Fig. 3-49
Hack
s
aw
Fig. 3-50
Indoor unit
Bottom
cover
Left
side
cover
Right
side
cover
Fig. 3-51
L-shaped tube
Fig. 3-52
L-shaped
tube
Fig. 3-53
07-115 SSHP_II
5/7/07
4:00 PM
Page 41