Sanyo 26KHS72R Installation Instructions - Page 58
Maximum Over Current Protection 15 A, Fuse Or Hacrtype Circuit Breaker
View all Sanyo 26KHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
07-115 SSHP_II 5/7/07 4:00 PM Page 58 Indoor Unit Type (B) Power Supply AWG #14 Trade Size of Conduit MOP (Fuse or HACR type circuit breaker) X, K, T, U Max. length 67 ft. 3/4 in. 15 A Control Wiring (C) Inter-Unit Control Wiring AWG #18 Use high voltage wire (300 V)*1 Max. 3,300 ft. (D) Remote Control Wiring AWG #18*2 (0.75 mm2) Max. 1,650 ft. (E) Control Wiring For Group Control AWG #18*2 - (0.75 mm2) Max. 1,650 - ft. (Total) *1 With ring-type wire terminal. *2 Wire joint connection. 5-3. Wiring System Diagrams Basic wiring diagram for standard control Remote controller D WHT 1 1 BLK 2 2 Outdoor unit INV unit Inter-unit power line L1 Indoor unit 208 / 230 V, 60 Hz B L2 1 1 2 2 G Grounding line C G U1 U1 U2 U2 Ground A L1 Power supply L2 208 / 230 V, 60Hz Grounding line NOTE CH Type 8P terminal board (1) Refer to Section 5-2. Recommended Wire Length and Wire Diameter for Power Supply System for the explanation of "A", "B", "C", "D", and "E", in the above diagrams. (2) Inter-Unit Control Wiring (C) and remote controller wiring (D), (E) have no polarity. But for other wiring, respect polarity. Be sure to connect as shown in the Wiring System Diagram. U1 U2 1 2 G L1 L2 Inter-unit Inter-unit Power wiring control wiring power wiring X, T, U Type 5P terminal board (3) In case of separate supply connection to indoor unit, over current protection must be provided between power source and indoor unit. MAXIMUM OVER CURRENT PROTECTION 15 A (FUSE OR HACRTYPE CIRCUIT BREAKER) 1 2 G U1 U2 Inter-unit Inter-unit power wiring control wiring Remote controller wiring K Type 4P terminal board U1 U2 1 2 G Inter-unit Inter-unit control wiring power wiring Remote controller wiring 58