Sony HDWS280 Product Manual (Operation Manual 1st Edition (Revised 5)) - Page 66

Items in the Extended Setup Menu

Page 66 highlights

9-4 Items in the Extended Setup Menu The expanded setup menu contains the following items. In the Settings column of the table, the factory setting is indicated by enclosing parenthesis. Note Items 900 to 999 are not applicable in 24PsF/23.98PsF mode. Items 100 to 199: Settings for the front panel Item Item name number Settings 101 SELECTION FOR Select how the unit enters the search mode. SEARCH DIAL ENABLE DIAL: Turning the search dial switches to search mode at all times except during recording/editing. [KEY]: The JOG/SHUTTLE button must be pressed to switch to search mode. 104 AUDIO MUTING TIME Select the length of time for which audio muting occurs when the unit switches to playback either from stopped or from still playback in the search mode. (for Betacam or Betacam SP playback only) [OFF]: Set the audio muting time to zero (i.e. no muting). 0.1S to 1.0S: Set the audio muting time from 0.1 second to 1.0 second, in 0.1-second increments. 105 REFERENCE SYSTEM Select whether or not to display a warning when the video/audio reference signal ALARM selected by OUT REF on the P2 VIDEO page of the function menu, is not supplied or is out of phase with the input video signal. OFF: No warning. [ON]: Flash the STOP button as a warning. 107 REC INHIBIT LAMP FLASHING Select whether or not to flash the REC INHI indicator when the erasure prevention plug on the cassette is pressed in. [OFF]: Do not flash the REC INHI indicator. ON: Flash the REC INHI indicator. 108 AUTO EE SELECT When a cassette is inserted and PB/EE on the HOME page of the function menu is set to EE, select the VTR modes in which input video and audio signals are automatically handled in E-E mode. [S/F/R]: In STOP/EJECT/F.FWD/REW modes STOP: In STOP/EJECT modes 109 FORCED EE WHEN TAPE During tape threading and unthreading, and when no cassette is inserted, select UNTHREAD whether the setting for PB/EE on the HOME page of the function menu controls the PB/ EE setting for output signals. OFF: Control by the function menu item PB/EE [ON]: No control (always E-E signal) 114 AUDIO MONITOR OUTPUT LEVEL Select whether the signal output from the AUDIO MONITOR OUTPUT connectors on the rear panel is adjustable with the LEVEL adjustment knob on the front panel. VAR: Adjustable [FIXED]: Not adjustable 118 KEY INHIBIT SWITCH Select which switches and buttons can be operated when the KEY INHI switch on the EFFECTIVE AREA front panel is set to ON. The following sub-items control different sets of switches and Sub-item buttons independently. 1 REMOTE SELECT Select whether the REMOTE button on the front panel is enabled. [DIS]: Disabled ENA: Enabled 2 FUNCTION-KEY Select whether the function buttons on the front panel are enabled. [DIS]: Disabled ENA: Enabled 3 MODE CONTROL Select whether the operative buttons and switches on the front panel are enabled. [DIS]: Disabled ENA: Enabled (except the REMOTE button and function buttons) Chapter 9 Setup Menus 66 Items in the Extended Setup Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

66
Items in the Extended Setup Menu
Chapter 9
Setup Menus
9-4
Items in the Extended Setup Menu
The expanded setup menu contains the following items.
In the Settings column of the table, the factory setting is
indicated by enclosing parenthesis.
Items 900 to 999 are not applicable in 24PsF/23.98PsF
mode.
Items 100 to 199: Settings for the front panel
Note
Item
number
Item name
Settings
101
SELECTION FOR
SEARCH DIAL ENABLE
Select how the unit enters the search mode.
DIAL:
Turning the search dial switches to search mode at all times except during
recording/editing.
[KEY]:
The JOG/SHUTTLE button must be pressed to switch to search mode.
104
AUDIO MUTING TIME
Select the length of time for which audio muting occurs when the unit switches to
playback either from stopped or from still playback in the search mode. (for Betacam or
Betacam SP playback only)
[OFF]:
Set the audio muting time to zero (i.e. no muting).
0.1S to 1.0S:
Set the audio muting time from 0.1 second to 1.0 second, in 0.1-second
increments.
105
REFERENCE SYSTEM
ALARM
Select whether or not to display a warning when the video/audio reference signal
selected by OUT REF on the P2 VIDEO page of the function menu, is not supplied or is
out of phase with the input video signal.
OFF:
No warning.
[ON]:
Flash the STOP button as a warning.
107
REC INHIBIT LAMP
FLASHING
Select whether or not to flash the REC INHI indicator when the erasure prevention plug
on the cassette is pressed in.
[OFF]:
Do not flash the REC INHI indicator.
ON:
Flash the REC INHI indicator.
108
AUTO EE SELECT
When a cassette is inserted and PB/EE on the HOME page of the function menu is set
to EE, select the VTR modes in which input video and audio signals are automatically
handled in E-E mode.
[S/F/R]:
In STOP/EJECT/F.FWD/REW modes
STOP:
In STOP/EJECT modes
109
FORCED EE WHEN TAPE
UNTHREAD
During tape threading and unthreading, and when no cassette is inserted, select
whether the setting for PB/EE on the HOME page of the function menu controls the PB/
EE setting for output signals.
OFF:
Control by the function menu item PB/EE
[ON]:
No control (always E-E signal)
114
AUDIO MONITOR
OUTPUT LEVEL
Select whether the signal output from the AUDIO MONITOR OUTPUT connectors on
the rear panel is adjustable with the LEVEL adjustment knob on the front panel.
VAR:
Adjustable
[FIXED]:
Not adjustable
118
KEY INHIBIT SWITCH
EFFECTIVE AREA
Select which switches and buttons can be operated when the KEY INHI switch on the
front panel is set to ON. The following sub-items control different sets of switches and
buttons independently.
Sub-item
1
REMOTE SELECT
Select whether the REMOTE button on the front panel is enabled.
[DIS]:
Disabled
ENA:
Enabled
2
FUNCTION-KEY
Select whether the function buttons on the front panel are enabled.
[DIS]:
Disabled
ENA:
Enabled
3
MODE CONTROL
Select whether the operative buttons and switches on the front panel are enabled.
[DIS]:
Disabled
ENA:
Enabled (except the REMOTE button and function buttons)