H to [19H] to 22H

Page 70 highlights

Items 600 to 699: Settings for a timecode generator Item Item name number 601a) VITC POSITION SEL-1 602a) VITC POSITION SEL-2 603 ID CODE PRESET 604 ID CODE SW 605 TCG REGEN MODE 606 TC OUTPUT SIGNAL IN REGEN MODE 607 U-BIT BINARY GROUP FLAG Settings In 59.94i/29.97PsF mode Select a line to insert the VITC in. (For SD output) 12H to [16H] to 20H: Select any line from 12 to 20. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. In 50i/25PsF mode Select a line to insert the VITC in. (For SD output) 9H to [19H] to 22H: Select any line from 9 to 22. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. In 59.94i/29.97PsF mode Select a line to insert the VITC in. (For SD output) 12H to [18H] to 20H: Select any line from 12 to 20. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. In 50i/25PsF mode Select a line to insert the VITC in. (For SD output) 9H to [21H] to 22H: Select any line from 9 to 22. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. Select whether or not to set the ID code. [OFF]: Do not set the ID code. ON: Set the ID code. To set the ID code: Display this item in the display window, and press the SET function button. The ID code setting mode is obtained. Select the digit to be set by pressing the T or t function button. When you select all digits, set the SET function button again. The ID code is stored and the ID code setting mode is terminated. Select whether or not to record the ID code set using item 603 in the user bits. [OFF]: Record the normal data in the user bits. ON: Record the ID code in the user bits. Select the signal to be regenerated when the timecode generator is in the regeneration mode (when the PRST/RGN on the P4 TC page of the function menu is set to LTC or VITC). [TC&UB]: Both the timecode and user bits are regenerated. TC: Only the timecode is regenerated. UB: Only the user bits are regenerated. Select the signal output from the TIME CODE OUT connector during normal (x1) speed playback. [TAPE]: During tape playback, the playback timecode signal is output without regeneration. REGEN: The playback timecode is output after regeneration. Select the user bits to be used in the timecode generated by the timecode generator. [000]: Character set not specified 001: 8-bit characters compliant with ISO 646 and ISO 2022 010: Undefined 011: Undefined 100: Undefined 101: SMPTE 262M page/line multiplex system 110: Undefined 111: Undefined Chapter 9 Setup Menus 70 Items in the Extended Setup Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

70
Items in the Extended Setup Menu
Chapter 9
Setup Menus
Items 600 to 699: Settings for a timecode generator
Item
number
Item name
Settings
601
a)
VITC POSITION SEL-1
In 59.94i/29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to [16H] to 20H:
Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
In 50i/25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to [19H] to 22H:
Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
602
a)
VITC POSITION SEL-2
In 59.94i/29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to [18H] to 20H:
Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
In 50i/25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to [21H] to 22H:
Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
603
ID CODE PRESET
Select whether or not to set the ID code.
[OFF]:
Do not set the ID code.
ON:
Set the ID code.
To set the ID code:
Display this item in the display window, and press the SET function button. The ID code
setting mode is obtained. Select the digit to be set by pressing the
T
or
t
function
button. When you select all digits, set the SET function button again. The ID code is
stored and the ID code setting mode is terminated.
604
ID CODE SW
Select whether or not to record the ID code set using item 603 in the user bits.
[OFF]:
Record the normal data in the user bits.
ON:
Record the ID code in the user bits.
605
TCG REGEN MODE
Select the signal to be regenerated when the timecode generator is in the regeneration
mode (when the PRST/RGN on the P4 TC page of the function menu is set to LTC or
VITC).
[TC&UB]:
Both the timecode and user bits are regenerated.
TC:
Only the timecode is regenerated.
UB:
Only the user bits are regenerated.
606
TC OUTPUT SIGNAL IN
REGEN MODE
Select the signal output from the TIME CODE OUT connector during normal (x1) speed
playback.
[TAPE]:
During tape playback, the playback timecode signal is output without
regeneration.
REGEN:
The playback timecode is output after regeneration.
607
U-BIT BINARY GROUP
FLAG
Select the user bits to be used in the timecode generated by the timecode generator.
[000]:
Character set not specified
001:
8-bit characters compliant with ISO 646 and ISO 2022
010:
Undefined
011:
Undefined
100:
Undefined
101:
SMPTE 262M page/line multiplex system
110:
Undefined
111:
Undefined