Items 400 to 499: Settings for preroll Item Item name number Settings 401 FUNCTION MODE AFTER Select the state that the unit goes into after a cuing-up operation. CUEUP [STOP]: Stop (the stop mode) STILL: Still playback (in search mode) Note When controlling this unit from an editor with the standard constants set, select STOP. 402 TIME REFERENCE FOR When prerolling a tape with timecode discontinuity, select whether or not to use CTL PREROLL pulses to count timecode from before a discontinuity. [CTL]: Use CTL pulses to count timecode. TC: Do not use CTL pulses to count timecode. 403 AUTOMATIC PREROLL Select whether or not the IN point is automatically set by pressing the PREROLL button, REFERENCE ENTRY when the IN point is not set before starting preroll. [DIS]: IN point is not set automatically. ENA: IN point is set automatically. 405 CUEUP BY CTL Select the tape transport mode when cuing. This setting is valid only when CTL/TC on the HOME page of the function menu is set to CTL. [CAP]: During cuing up, the tape transport is in the pinch ON state (maximum tape speed 10 times normal). REEL: During cuing up, the tape transport is in the pinch OFF state. As the tape approaches the cue up point and the tape speed drops, the tape transport switches to the pinch ON state.a) To give priority to editing accuracy, select CAP. a) When controlling with an editor such as a BVE-2000, select REEL for quick cueup. Items 500 to 599: Settings for tape protection Item Item name number 501 STILL TIMER 502 TAPE PROTECTION MODE FROM SEARCH 503 TAPE PROTECTION MODE FROM STOP Settings Select the time delay from the tape transport stopping (either the stop mode or the still playback mode in search mode) until the unit automatically switches to the tape protection mode, in order to protect the video heads and the tape. 0.5S to [8M] to 30M: Set the value in the range 0.5 seconds to 30 minutes. Select the operation of the protection mode to protect the video heads and tape when in the still playback mode in search mode (jog/shuttle). [STEP]: Step forward at 0.2 time of the normal speed for 0.2 second. STDBY: Switch to Standby OFF mode (the unit not on standby). T.REL: Switch to tension release mode (the tape tension slackened). Select the operation of the protection mode to protect the video heads and tape when stopped (the stop mode). [STDBY]: Switch to Standby OFF mode (the unit not on standby). T.REL: Switch to tension release mode (the tape tension slackened). STEP: Step forward at 0.2 time of the normal speed for 0.2 second. Chapter 9 Setup Menus 69 Items in the Extended Setup Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

69
Items in the Extended Setup Menu
Chapter 9
Setup Menus
Items 400 to 499: Settings for preroll
a)
When controlling with an editor such as a BVE-2000, select REEL for
quick cueup.
Items 500 to 599: Settings for tape protection
Item
number
Item name
Settings
401
FUNCTION MODE AFTER
CUEUP
Select the state that the unit goes into after a cuing-up operation.
[STOP]:
Stop (the stop mode)
STILL:
Still playback (in search mode)
Note
When controlling this unit from an editor with the standard constants set, select STOP.
402
TIME REFERENCE FOR
PREROLL
When prerolling a tape with timecode discontinuity, select whether or not to use CTL
pulses to count timecode from before a discontinuity.
[CTL]:
Use CTL pulses to count timecode.
TC:
Do not use CTL pulses to count timecode.
403
AUTOMATIC PREROLL
REFERENCE ENTRY
Select whether or not the IN point is automatically set by pressing the PREROLL button,
when the IN point is not set before starting preroll.
[DIS]:
IN point is not set automatically.
ENA:
IN point is set automatically.
405
CUEUP BY CTL
Select the tape transport mode when cuing. This setting is valid only when CTL/TC on
the HOME page of the function menu is set to CTL.
[CAP]:
During cuing up, the tape transport is in the pinch ON state (maximum tape
speed 10 times normal).
REEL:
During cuing up, the tape transport is in the pinch OFF state. As the tape
approaches the cue up point and the tape speed drops, the tape transport switches
to the pinch ON state.
a)
To give priority to editing accuracy, select CAP.
Item
number
Item name
Settings
501
STILL TIMER
Select the time delay from the tape transport stopping (either the stop mode or the still
playback mode in search mode) until the unit automatically switches to the tape
protection mode, in order to protect the video heads and the tape.
0.5S to [8M] to 30M:
Set the value in the range 0.5 seconds to 30 minutes.
502
TAPE PROTECTION
MODE FROM SEARCH
Select the operation of the protection mode to protect the video heads and tape when in
the still playback mode in search mode (jog/shuttle).
[STEP]:
Step forward at 0.2 time of the normal speed for 0.2 second.
STDBY:
Switch to Standby OFF mode (the unit not on standby).
T.REL:
Switch to tension release mode (the tape tension slackened).
503
TAPE PROTECTION
MODE FROM STOP
Select the operation of the protection mode to protect the video heads and tape when
stopped (the stop mode).
[STDBY]:
Switch to Standby OFF mode (the unit not on standby).
T.REL:
Switch to tension release mode (the tape tension slackened).
STEP:
Step forward at 0.2 time of the normal speed for 0.2 second.