Compaq ProLiant 1000 User Guide: Online Storage Controller Recovery Option - Page 22
Configuration Options
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
2-4 Functionality and Configuration Options Configuration Options This section outlines the configuration guidelines involved in establishing highly reliable I/O using OSCRO. Table 2-1 lists the RAID options available and details the requirements and benefits of each option. Raid Level 0 0 1 1 5 5 Table 2-1 Configuration Options Controller Controllers Pairing Required No 1 Min. # of Drives 1 Storage Space Overhead for Redundancy 0% Recommended Comments No Data unavailable if drive or controller fails. Yes 2 1 0% No Data unavailable if drive fails. No 1 2 50% No Data unavailable if controller fails. Yes 2 2 50% Yes Complete redundancy, high overhead. No 1 3 33% to 7% No Data unavailable if controller fails. Yes 2 3 33% to 7% Yes Complete redundancy, lowest overhead.