Compaq ProLiant 1000 User Guide: Online Storage Controller Recovery Option - Page 71
Recoving from Mass Storage Controller Failure
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
6-2 Recoving from Mass Storage Controller Failure 4. Use the Online Storage Controller Recovery Utility to perform a manual Switch operation, thus making the controller the active controller of the controller pair (see Figure 6-1). 1 0 1 0 Active Standby Failed 1 0 1 Active 1 0 1 Active 1 0 1 Standby Active 1 1 1 1 0 0 0 0 1 1 1 1 Device Driver Device Driver Device Driver Device Driver A controller pair is established. If a controller fails, standby becomes active. PCI slot powered Controller replaced and down and failed controller pair is controller removed. re-established. Figure 6-1. Compaq PCI Hot Plug Technology Recovery from Controller Failure with OSCRO Using this procedure, the fault-tolerant state of the I/O subsystem is restored without shutting down the system or interrupting the availability of the data.