Compaq ProLiant 1000 User Guide: Online Storage Controller Recovery Option - Page 40

Table 3-1, Compaq SSD for Windows NT Components

Page 40 highlights

3-12 Planning and Installing the Online Storage Controller Table 3-1 Compaq SSD for Windows NT Components SSD Component Uniprocessor/Multiprocessor HAL and Kernel Required for OSCRO No Description Allows you to upgrade or downgrade the HAL and kernel to match the configuration of the server. HAL Recovery Option No Allows a user with a multiprocessor system to recover from blue- screen traps resulting from mismatched HAL and hardware, mismatched HAL and kernel, and HAL corruption. Although not required for OSCRO, it is highly recommended for multiprocessor- capable servers. Compaq System Management Yes Driver This component is required on the local server when implementing OSCRO. It provides a communications path between the SMART-2 device drivers and the Compaq Online Storage Controller Recovery Utility. Compaq Remote Monitor Yes Service The CPQRCMC service is required when implementing OSCRO on the local server or when setting up remote management capability. CPQRCMC acts as the central communications point for the Compaq Online Storage Controller Recovery Utility as well as the PCI Hot Plug Utility. Compaq PCI Hot Plug No The PCI Hot Plug utility allows you to control the PCI Hot Plug slots on the local system or on a remote system. Although not required for OSCRO, it is useful in the OSCRO environment to prevent downtime. Continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3-12
Planning and Installing the Online Storage Controller
Table 3-1
Compaq SSD for Windows NT Components
SSD Component
Required
for
OSCRO
Description
Uniprocessor/Multiprocessor
HAL and Kernel
No
Allows you to upgrade or downgrade the HAL and kernel to match
the configuration of the server.
HAL Recovery Option
No
Allows a user with a multiprocessor system to recover from blue-
screen traps resulting from mismatched HAL and hardware,
mismatched HAL and kernel, and HAL corruption.
Although not
required for OSCRO, it is highly recommended for multiprocessor-
capable servers.
Compaq System Management
Driver
Yes
This component is required on the local server when implementing
OSCRO.
It provides a communications path between the SMART-2
device drivers and the Compaq Online Storage Controller Recovery
Utility.
Compaq Remote Monitor
Service
Yes
The CPQRCMC service is required when implementing OSCRO on
the local server or when setting up remote management capability.
CPQRCMC acts as the central communications point for the Compaq
Online Storage Controller Recovery Utility as well as the PCI Hot Plug
Utility.
Compaq PCI Hot Plug
No
The PCI Hot Plug utility allows you to control the PCI Hot Plug slots
on the local system or on a remote system.
Although not required
for OSCRO, it is useful in the OSCRO environment to prevent
downtime.
Continued