HP StorageWorks 2/32 SAN switch 2/32 version 4.0.x installation guide - Page 33

Mount Kit. Secure the inner slide rail to the switch, see, Locate three Phillips head

Page 33 highlights

Installing the SAN Switch 2/32 Caution: HP recommends installing the SAN Switch 2/32 so that the port side of the switch slides out the rear of the rack (as described in step 1a below). In this way, the switch faces the aisle where exhaust air is released. Air intake and exhaust for all components in the rack should flow in the same direction. a. To allow the port side of the switch to slide out the rear of the rack: Orient the inner slide rail with the end containing the lock release lever towards the power supply end of the switch. b. To allow the power supply side of the switch to slide out the front of the rack: Orient the inner slide rail with the end containing the lock release lever towards the port end of the switch. 2. Locate three Phillips head, 8-32 x 3/16 inch screws provided in the Rack Mount Kit. Secure the inner slide rail to the switch, see Figure 4. 3. Tighten the screws and torque to 15 inch-pounds. SHR-2575A Figure 4: Securing the inner slide rails to the switch 4. Repeat steps 1 and 2 to attach the second inner slide rail to the switch. Make sure to orient the second inner slide rail in the same way you positioned the first (based on 1a or 1b above). SAN Switch 2/32 Installation Guide 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Installing the SAN Switch 2/32
33
SAN Switch 2/32 Installation Guide
Caution:
HP recommends installing the SAN Switch 2/32 so that the port side
of the switch slides out the rear of the rack (as described in step 1a below). In
this way, the switch faces the aisle where exhaust air is released. Air intake
and exhaust for all components in the rack should flow in the same direction.
a.
To allow the port side of the switch to slide out the rear of the rack:
Orient the inner slide rail with the end containing the lock release lever
towards the power supply end of the switch.
b.
To allow the power supply side of the switch to slide out the front of the
rack:
Orient the inner slide rail with the end containing the lock release lever
towards the port end of the switch.
2.
Locate three Phillips head, 8-32 x 3/16 inch screws provided in the Rack
Mount Kit. Secure the inner slide rail to the switch, see
Figure 4
.
3.
Tighten the screws and torque to 15 inch-pounds.
Figure 4:
Securing the inner slide rails to the switch
4.
Repeat steps 1 and 2 to attach the second inner slide rail to the switch. Make
sure to orient the second inner slide rail in the same way you positioned the
first (based on 1a or 1b above).
SHR-2575A