HP StorageWorks 2/32 SAN switch 2/32 version 4.0.x installation guide - Page 87
Power Supply Specifications
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
Technical Specifications Power Supply Specifications Table 8 lists power supply specifications. The power supply is universal and capable of functioning worldwide without using voltage jumpers or switches. It meets IEC 61000-4-5 surge voltage requirements. The power supply has its own built-in fan for cooling, pushing the air towards the front of the switch. Table 8: Power Supply Specifications Specification Outlet Maximum output Maximum system power consumption Input voltage Input line frequency Harmonic distortion Btu rating at 80% efficiency Inrush current Input line protection Value Correctly wired and earth-grounded 300 watts, with internal fans operating 190-220 watts (with some variation depending on transceiver vendor) 100-240 VAC (nominal 80% efficiency) auto-ranging 47-63 Hz Active power factor correction per EN61000-3-2 220 watts / 0.8 x 3.412 Btu/hr/watts = 938 Btu/hr Maximum of 15 amps for periods longer than 300 microseconds, at 50 degrees Celsius, hot or cold start Fused in both hot and neutral lines, using independent fuses . SAN Switch 2/32 Installation Guide 87