HP StorageWorks 2/32 SAN switch 2/32 version 4.0.x installation guide - Page 76
Fan Assemblies, In Web Tools, click the Power Status icon
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Managing the SAN Switch 2/32 The Fabric OS identifies the power supplies as follows (viewing the switch from the non-port side): ■ Power supply #1 is on the right when viewing the switch from the non-port side. ■ Power supply #2 is on the left when viewing the switch from the non-port side. To determine whether a power supply requires replacing: ■ Check the Power Supply LED next to the AC switch ■ Enter the psshow command ■ In Web Tools, click the Power Status icon Fan Assemblies The three fan assemblies are hot-swappable if replaced one at a time. The fan assemblies are identical and fit into any fan assembly slot; see Figure 19. 1 2 3 4 5 SHR-2580A 1 Power supply #2 3 Fan assembly containing fans 3,4 2 Fan assembly containing fans 5,6 4 Fan assembly containing fans 1,2 5 Power supply #1 Figure 19: Power supplies and fan assemblies locations Each fan assembly contains two fans, identified by Fabric OS as follows (viewing the switch from the non-port side assembly on the right contains fans #1 and #2). ■ The fan assembly in the center contains fans #3 and #4. ■ The fan assembly on the left contains fans #5 and #6. 76 SAN Switch 2/32 Installation Guide