HP StorageWorks 2/32 SAN switch 2/32 version 4.0.x installation guide - Page 36

Adjust the outer slide rail's length to fit the length of the rack.

Page 36 highlights

Installing the SAN Switch 2/32 Note: Before starting this procedure, verify that two of the slide mount L-brackets are preinstalled at the end of each outer slide rail; see Figure 6. The L-brackets are necessary to attach the outer rails to the rack. 1. Determine the appropriate placement for the switch inside the rack. The HP 9000 Series Rack's rails are divided into Units (Us). Each U is marked with a small, round hole and three square openings for mounting equipment. Note: The SAN Switch 2/32 requires 1.5 Units of rack space. 2. Locate the small, round marker hole on the rack's rails, which coincides with the location selected in step 1. Each marker hole delineates the beginning of one U. 3. Insert one square alignment washer on each of the eight 10-32 x 3/8 inch Phillips head screws. Note: The square alignment washers are mandatory for proper switch alignment. 4. Adjust the outer slide rail's length to fit the length of the rack. 5. Position one of the outer slide rails in the rack, as described below: a. To allow the switch's port end to slide out the back of the rack, orient with the closed end of the outer slide rail towards the front of the rack. b. To allow the power supply end to slide out the front of the rack, orient the closed end of the outer slide rail towards the back of the rack. 6. Holding the outer slide rail in place, insert one 3-hole bar nut in between the rack's rail and the L-bracket at the end of the outer slide rail, Figure 6. Note: Position the square alignment washers onto the Phillips head 10-32 x 3/8 inch screws, as described in step 3. The square alignment washers are mandatory for proper switch alignment. 36 SAN Switch 2/32 Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Installing the SAN Switch 2/32
36
SAN Switch 2/32 Installation Guide
Note:
Before starting this procedure, verify that two of the slide mount L-brackets are
preinstalled at the end of each outer slide rail; see Figure 6. The L-brackets are
necessary to attach the outer rails to the rack.
1.
Determine the appropriate placement for the switch inside the rack. The HP
9000 Series Rack’s rails are divided into Units (Us). Each U is marked with a
small, round hole and three square openings for mounting equipment.
Note:
The SAN Switch 2/32 requires 1.5 Units of rack space.
2.
Locate the small, round marker hole on the rack’s rails, which coincides with
the location selected in step 1. Each marker hole delineates the beginning of
one U.
3.
Insert one square alignment washer on each of the
eight 10-32 x 3/8 inch Phillips
head screws.
Note:
The square alignment washers are mandatory for proper switch alignment.
4.
Adjust the outer slide rail’s length to fit the length of the rack.
5.
Position one of the outer slide rails in the rack, as described below:
a.
To allow the switch’s port end to slide out the back of the rack, orient with
the closed end of the outer slide rail towards the front of the rack.
b.
To allow the power supply end to slide out the front of the rack, orient the
closed end of the outer slide rail towards the back of the rack.
6.
Holding the outer slide rail in place, insert one 3-hole bar nut in between the
rack’s rail and the L-bracket at the end of the outer slide rail,
Figure 6
.
Note:
Position the square alignment washers onto the Phillips head 10-32 x 3/8 inch
screws, as described in step 3. The square alignment washers are mandatory for
proper switch alignment.