HP StorageWorks 4/16 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 175
Replacing a control processor blade (CP8), Workstation computer
View all HP StorageWorks 4/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 175 highlights
2. Slide the filler panel into the slot until it is firmly seated. 3. Tighten the thumb screw at the bottom of the panel. 4. Replace the chassis door (see "Installing the chassis door" on page 170). Figure 66 DC04 SAN Director blade filler panel Replacing a control processor blade (CP8) This section describes how to remove and replace a control processor (CP8) blade. Each DC04 SAN Director has two CP8 blades, which are located in slot 4 and slot 5. NOTE: If the new CP blade does not have the same firmware as the active CP blade, you must upgrade the new blade to the active CP blade's firmware version. The replacement procedure for the CP blade takes approximately 30 minutes. The following items are required for the CP blade replacement: • ESD grounding strap • Workstation computer • Serial cable • IP address of an FTP server for backing up the DC04 SAN Director configuration • Phillips #2 screwdriver HP StorageWorks DC and DC04 SAN Backbone Director Switches 175