HP StorageWorks 4/16 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 21

Port side of the DC SAN Director, own connector

Page 21 highlights

• Improved cable management using a re-designed cable management comb and chassis door • Constant intake andField-replaceable Unit (FRU) temperature monitoring • Redundant AC primary power connections to ensure high availability. Each power supply has its own connector, so the number of primary power connections varies from two to four Port side of the DC SAN Director NOTE: Airflow in the DC SAN Director is from the non-port (non-cable) side to the port (cable) side and out the exhaust vent. Figure 1 shows a sample configuration of the port side of the DC SAN Director. 1 2 3 4 5 25369a Figure 1 Port side of the DC SAN Director (sample configuration) 1. Exhaust Vent 3. CP blade (CP8 5. Cable management comb 2. Core switch blade (CR8) 4. FC8-48 Director blade HP StorageWorks DC and DC04 SAN Backbone Director Switches 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256

Improved cable management using a re-designed cable management comb and chassis door
Constant intake andField-replaceable Unit (FRU) temperature monitoring
Redundant AC primary power connections to ensure high availability. Each power supply has its
own connector, so the number of primary power connections varies from two to four
Port side of the DC SAN Director
NOTE:
Airflow in the DC SAN Director is from the non-port (non-cable) side to the port (cable) side and out
the exhaust vent.
Figure 1
shows a sample configuration of the port side of the DC SAN Director.
25369a
1
2
3
4
5
Figure 1 Port side of the DC SAN Director (sample configuration)
2. Core switch blade (CR8)
1. Exhaust Vent
4. FC8-48 Director blade
3. CP blade (CP8
5. Cable management comb
HP StorageWorks DC and DC04 SAN Backbone Director Switches
21