HP StorageWorks 4/16 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 205
Verifying that the configuration of the fabric is correct, file created earlier. In particular
View all HP StorageWorks 4/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 205 highlights
Verifying that the configuration of the fabric is correct Copying the command outputs from this section into a file is recommended. To verify correct configuration of the fabric: 1. Create an "after" SAN profile by entering the following commands and copying the output to a text file named SANafter.txt: • nsShow • nsAllShow • switchShow • fabricShow rsl8-st03-dcx-1:admin> nsshow Type Pid COS PortName NodeName TTL(sec) N 020f00; 3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na Fabric Port Name: 20:0f:00:60:69:90:03:f0 rsl8-st03-dcx-1:admin> nsallshow { 020f00 021fda 021fdc 021fe0 021fe1 5 Nx_Ports in the Fabric} rsl8-st03-dcx-1:admin> switchshow switchName: rsl8-st03-dcx-01 rsl8-st03-dcx-1:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name rsl8-st03-dcx-1:admin> 2. Determine any differences between the information in the SANafter.txt file and the information in the SANbefor.txt file created earlier. In particular, look for differences in the following: • Device types • Number of devices • ISL and port states • Number of switches in the fabric HP StorageWorks DC and DC04 SAN Backbone Director Switches 205