HP StorageWorks 4/16 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 227
Recommendations for cable management, and are not assigned port numbers or area
View all HP StorageWorks 4/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 227 highlights
5. Verify the correct operation of the FR4-18i blade ports by typing the switchShow command from the Director command prompt. This command provides information about switch and port status. Once the FR4-18i blade is installed and fully configured in a Director, the switchShow command displays 32 Fibre Channel ports (port numbers 0 through 31) and two GbE ports. The first 16 Fibre Channel ports are physical ports on the FR4-18i blade, Ports 16-23 are virtual ports associated with the GE0 physical GbE link and ports 24-31 are virtual ports associated with GE1 physical GbE link. The GbE ports are displayed as ge0 and ge1 and are not assigned port numbers or area numbers. Recommendations for cable management Manage cables as follows: • Plan cable management before installing the blade. • Leave at least one meter of slack for each port cable. This provides room to remove and replace the blades, and helps prevent the cables from being bent to less than the minimum bend radius. HP StorageWorks DC and DC04 SAN Backbone Director Switches 227