HP StorageWorks 4/16 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 201

Verifying that the system is operating correctly, Type the chassis serial number at

Page 201 highlights

1. Open a CLI session (Telnet or serial) to the DC04 SAN Director and log in as root: The root and factory account disclaimer is displayed. • Log in using Telnet. Use the IP address of the DC04 SAN Director through Telnet and log in as root. Fabric OS (rsl8-st03-dcx-1) login: root Password: Disclaimer for Root and Factory Accounts Usage! This Fibre Channel switch is equipped with Root and Factory accounts that are intended for diagnostics and debugging purposes solely by the Equipment vendor's trained engineers. Improper use of the functionality made available through the Root or Factory account could cause significant harm and disruption to the operation of the SAN fabric. Your use of the functionality made available through the Root or Factory account is at your sole risk and you assume all liability resulting from such use. The Equipment vendor shall have no liability for any losses or damages arising from or relating to the use of the Root or Factory account (and the functionality enabled thereby) by anyone other than the Equipment vendor's authorized engineers. Proceeding with the usage of this switch as the Root or Factory user explicitly indicates your agreement to the terms of this disclaimer. rsl8-st03-dcx-1:root> 2. Change the factory serial number to the serial number of the new chassis: a. Type fruInfoSet chassis 1 at the prompt. b. Type the OEM serial number, if any, at the SN prompt. c. Type the chassis serial number at the Chassis SN: prompt. d. Verify that the command redisplays the correct serial numbers. rsl8-st03-dcx-1:root> fruinfoset chassis 1 ID: (none) > PN: (none) > SN: (none) > OEMssn12345 RV: (none) > Chassis SN: (none) > FT00X8008A4 New FRU Info for: chassis(wwn) 1 ID: none PN: none SN: OEMssn12345 RV: none Chassis SN: FT00X8008A4 rsl8-st03-dcx-1:root> 3. Verify that the chassis serial number has been entered correctly by typing chassisShow at the prompt. Verifying that the system is operating correctly To verify that the DC04 SAN Director is operating correctly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 201

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256

1.
Open a CLI session (Telnet or serial) to the DC04 SAN Director and log in as
root
:
The root and factory account disclaimer is displayed.
Log in using Telnet.
Use the IP address of the DC04 SAN Director through Telnet and log in as
root
.
Fabric OS (rsl8-st03-dcx-1)
login:
root
Password:
Disclaimer for Root and Factory Accounts Usage!
This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.
Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.
rsl8-st03-dcx-1:root>
2.
Change the factory serial number to the serial number of the new chassis:
a.
Type
fruInfoSet chassis 1
at the prompt.
b.
Type the OEM serial number, if any, at the
SN
prompt.
c.
Type the chassis serial number at the
Chassis SN:
prompt.
d.
Verify that the command redisplays the correct serial numbers.
rsl8-st03-dcx-1:root>
fruinfoset chassis 1
ID: (none) >
PN: (none) >
SN: (none) > OEMssn12345
RV: (none) >
Chassis SN: (none) > FT00X8008A4
New FRU Info for: chassis(wwn) 1
ID: none
PN: none
SN: OEMssn12345
RV: none
Chassis SN: FT00X8008A4
rsl8-st03-dcx-1:root>
3.
Verify that the chassis serial number has been entered correctly by typing
chassisShow
at the
prompt.
Verifying that the system is operating correctly
To verify that the DC04 SAN Director is operating correctly:
HP StorageWorks DC and DC04 SAN Backbone Director Switches
201