installation guide hp StorageWorks director 2/64 Product Version: FW V05.01.00-24/HAFM SW V07.01.00-09 Third Edition (June 2003) Part Number: AA-RSNGC-TE/958-000289-001 This guide provides procedures for setting up, configuring, and managing the HP StorageWorks Director 2/64. - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 2
set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A. Director 2/64 Installation Guide Third Edition (June 2003) Part Number: AA-RSNGC-TE/958-000289-001 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 3
Symbols 14 Rack Stability 16 Getting Help 17 HP Technical Support 17 HP Storage Website 17 HP Authorized Reseller 17 1 Overview 19 Director Description 20 Features 21 Director Management 21 Error-Detection, Reporting, and Serviceability 22 Zoning 24 Multi-Switch Fabrics 25 Hardware - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 4
Tools Supplied by Service Personnel 36 Optional Kits 37 2 Installing and Configuring the Director 2/64 39 Installation the Rack Mounting Procedure 54 HP System/e and Industry-Standard 19-in Rack Installation 57 Install the Anti-tip Feet on a HP System/e Rack 57 Install 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 5
Between the Director and HAFM Server 81 Set Director Date and Time 83 Set Date and Time Manually 84 Synchronize Date and Time 85 Frequently Used HAFM Settings 86 Set the Director Online 87 Set Alerts 103 Modify Alerts 108 Activate or Deactivate Alerts 108 Director 2/64 Installation Guide 5 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 6
Spécification ATI Classe A (France 131 Canadian Notice (Avis Canadien 131 Class A Equipment 131 Class B Equipment 131 European Union Notice 132 Japanese Notice 132 6 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 7
contents for a 9000/10000/11000 rack installation 47 9 Carton contents for a HP rack system/e or industry-standard 19-in rack installation . . . 49 10 58 14 AC power connections 59 15 Mounting anti-tip feet for a HP rack system/e rack 60 16 Rail tray mounting location requirement 61 17 Attaching - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 8
Contents 20 Preparing the front rack columns 64 21 Preparing the rear rack columns 65 22 Installing the rack mounting brackets on the switch 66 23 Port Properties dialog box 115 56 HAFM remote client install 117 57 Enter Network Password dialog box 120 8 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 9
160 81 Modify Firmware Description dialog box 162 82 Backup and Restore Configuration dialog box 165 83 Send Firmware confirmation box 165 Tables 1 Document Conventions 15 2 Director 2/64 Optional Kits 38 3 Shipping Carton Contents for an HP 9000/10000/11000 Rack 48 4 Parts for Installing in - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 10
Contents 10 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 11
, and verifying operation of the HP StorageWorks Director 2/64. The Director 2/64 switch connects storage deAvbiocuetst,hihs oGsutisd,eand servers in a SAN. The director is easily managed and configured to optimize the performance of your SAN. "About this Guide" topics include: ■ Overview, page 12 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 12
This guide is part of a documentation set that supports the Director 2/64. It is intended for use by trained service and HP StorageWorks Director 2/64 Release Notes. For the latest information, documentation, and firmware releases, please visit the HP StorageWorks website: http://h18006.www1.hp - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 13
About this Guide Conventions Conventions consist of the following: ■ Document Conventions ■ Text Symbols ■ font> Blue, underlined sans serif font text: http://www.hp.com Text Symbols The following symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 14
with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock hazards, do hot component, allow the surface to cool before touching. 14 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 15
About this Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources of power. injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. Director 2/64 Installation Guide 15 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 16
About this Guide Rack Stability Rack stability protects personnel and equipment. WARNING: To reduce the risk of personal injury or damage to the equipment, be at any time. A rack may become unstable if more than one rack component is extended for any reason. 16 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 17
still have a question after reading this guide, contact an HP authorized service provider or access our website: http://www.hp.com. HP Technical Support Telephone numbers for worldwide technical support are listed on the following HP website: http://www.hp.com/support/. From this website, select the - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 18
About this Guide 18 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 19
Overview 1 1 This chapter contains the following HP StorageWorks Director 2/64 information: ■ Director Description, page 20 ■ Features, page 21 ■ Hardware Components, page 27 ■ Tools and Test Equipment, page 34 ■ Optional Kits, page 37 Director 2/64 Installation Guide 19 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 20
and controlled through a HAFM server with the High Availability Fabric Manager (HAFM) and Director 2/64 Product Manager applications installed. The HAFM server is a notebook personal computer (PC) that provides through the customer's local area network (LAN). 20 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 21
the HP StorageWorks SNMP Reference Guide for supports configuration, statistics monitoring, and basic operation of the director, but does not offer all the capabilities of the Director 2/64 Product Manager application. Administrators launch the EWS interface Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 22
to guide users through tasks. Refer to the HP StorageWorks CLI Reference Guide for and Serviceability The director provides the following error-detection, reporting, and serviceability at the HAFM server or remote workstation. ■ Diagnostic software that performs power-on self-tests (POSTs) and - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 23
support personnel or administrators) through e-mail messages or the call-home feature at the HAFM server. ■ An RS-232 maintenance port at the rear of the director (port access is password-protected) that enables installation or service problems. backup FRU daily. A backup 64 Installation Guide 23 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 24
state changes and failure conditions. Note: For more information about SNMP support provided by HP products, refer to the HP StorageWorks SNMP Reference Guide for Directors and Edge Switches. The director supports a name server zoning feature that partitions attached devices into restricted-access - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 25
of one or more interconnected directors or switch elements is called a fabric. Operational software provides the ability to interconnect directors (through expansion port (E_Port) connections) to form and if zones with the same name have identical elements. Director 2/64 Installation Guide 25 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 26
or director does not respond to a verification request. - ELP retransmission failure timeout-A director that exhibits a hardware failure or connectivity problem cannot transmit or receive Class F frames. The director did not receive a response to multiple exchange link protocol (ELP) frames, did - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 27
replacement of FRUs. The following sections define Director 2/64 main components. Front View Figure 1 shows Director 2/64 components accessible from the front of the Director. kits 9000/10000/11000 and M-Series only. Figure 1: Director components-front Director 2/64 Installation Guide 27 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 28
Ethernet Local Area Network (LAN). Each CTP2 card provides System Services Processor (SSP) and Embedded Port (EP) subsystems. The SSP OFF on the backup CTP2. The amber LED FLASHES if beaconing is enabled. Front Bezel The bezel at the front of the Director 2/64 includes two 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 29
mount kits for the 9000/10000/11000 and M-Series racks only. Power Supplies The Director 2/64 uses redundant, load-sharing power supplies which step down and rectify facility input power to provide Regulations (CFR), Subpart J as of the date of manufacture. Director 2/64 Installation Guide 29 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 30
and ISLs. Figure 2 shows the faceplate of an UPM. 1 UPM 2 1 Card LED 2 Port LEDs 3 Port Connectors (G_Ports) 3 Figure 2: UPM card LEDs and connectors 30 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 31
over extended long distances (up to 35 kilometers) through 9-µm single-mode fiber. Rear View Figure 3 shows the components accessible from the rear of the Director 2/64. Director 2/64 Installation Guide 31 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 32
on and operating, provided the module is replaced within 10 minutes (after which software powers off the director). An amber LED for each fan module turns ON port to any other director port. Connections are established without software intervention. The assembly accepts a connection request from a - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 33
status for each director port. The backup SBAR takes over operation if the active transmission without interruption. The transition to the backup assembly is transparent to attached devices. Each The breaker is set manually, or is automatically tripped by internal software if thermal sensors indicate - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 34
of the tools may be required to perform test, installation, service, or verification tasks. ■ Torque tool with hexagonal adapter-The not use an Allen wrench or torque tool designed for use with another HP product. Use of the wrong tool may overtighten and damage logic cards. 64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 35
configure director network addresses and acquire event log information through the maintenance port. The cable has nine conductors and DB-9 male and female connectors. Director 2/64 Installation Guide 35 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 36
Use of the tools may be required to perform one or more test, service, or verification tasks. ■ Scissors or pocket knife-A sharp cutting edge ( -The kit contains tools and instructions to clean fiber-optic cable, connectors, loopback plugs, and protective plugs. 36 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 37
Kits Contact your Hewlett-Packard authorized service provider to purchase the following optional Director 2/64 kits. See Table 2 for descriptions of Director 2/64 optional kits. Table 2: Director 2/64 Optional Kits Supporting Kit Description HP Open Trunking License. Provides a license to - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 38
Overview 38 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 39
2 This chapter describes tasks to install, configure, and verify operation of the Director 2/64. This chapter describes the following: ■ Installation Options, page 40 ■ Review Installation Requirements, , page 112 ■ Using HAFM from a Remote Location, page 114 Director 2/64 Installation Guide 39 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 40
Installing and Configuring the Director 2/64 Installation Options The director is installed in one of two and an optional HAFM server are delivered to the customer facility for installation in a HP or customer-supplied equipment rack. Rack mount hardware is provided in the shipping container. - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 41
switch: ■ Prepare a site plan. Consult the HP StorageWorks SAN High Availability Planning Guide. ■ Verify that required technical personnel are available and : ■ Lift device (recommended). ■ Director 2/64. ■ A HP 9000, HP 10000, HP 11000, HP M-Series, HP system/e, or industry-standard 19-in rack, - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 42
64 - A minimum depth of 24.5 in. - 19 in wide. - A minimum opening size of 10U available (9U for the director and 1U for the rail tray kit). ■ Two power outlets or different branches (for redundancy). ■ Torque driver with cross-tip bit the Director 2/64. ■ Standard serial communication software (for - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 43
Installing and Configuring the Director 2/64 Select an Operating Location Install the director in a secure or limited-access area to ensure that : 100 to 120 or 200 to 240 VAC ■ Input frequency: 50/60 Hz Caution: Do not block Director 2/64 air vents. The switch uses ambient air for cooling. Director - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 44
shown in Figure 8 and Table 3 for the HP 9000/10000/11000 rack kit and Figure 9 and Table 4 for the HP system/e and industry-standard 19-in rack. Note: If any items are damaged or missing, please contact a Hewlett-Packard authorized service provider or reseller. 44 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 45
Installing and Configuring the Director 2/64 s. Figure 8: Carton contents for a 9000/10000/11000 rack installation Director 2/64 Installation Guide 45 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 46
CD containing firmware, license, documentation 2 HP StorageWorks Director 2/64 Installation Guide 3 Two Power Distribution Unit (PDU) power cords 4 Two standard AC power cords 5 Four multi-mode, short-wave loopback plugs 6 One torque driver with integrated 5/32" bit 7 One 10-foot null - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 47
s. 5 Installing and Configuring the Director 2/64 1 2 3 4 Figure 9: Carton contents for a HP system/e or industry-standard 19-in rack installation Director 2/64 Installation Guide 47 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 48
System/e and Industry-Standard 19-in Rack Label Item 1 HP StorageWorks Director 2/64 (part number: A6534-62001) 4 Rail Tray Kit (part number: A6534-60016): ■ One rail tray ■ Two sheet metal nuts ■ Eight 10-32 Phillips flat-head screws (includes extras) 48 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 49
64 Install the Director in a Rack The following sections provide instructions for installing the Director 2/64 in either the 9000/10000/11000 rack or in the HP HP StorageWorks M-Series Rack Mount Kit Installation Instructions. Required Tools Obtain the following tools: ■ For a HP the Director 2/64. ■ - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 50
is 9U (15.75 inches) high. 9000/10000/11000 Rack Installation To install the director in a HP 9000/10000/11000 rack, complete the procedures in the following sections: ■ Install the Shelf Brackets in a hole delineates the beginning of one rail unit, or U. 50 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 51
Installing and Configuring the Director 2/64 3. Locate the square opening in the rail that corresponds with the appropriate marker hole, as shown in Figure hardware includes: ■ Two front mounting brackets ■ Two rear mounting plates ■ Ten cage nuts ■ Eight screws Director 2/64 Installation Guide 51 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 52
Installing and Configuring the Director 2/64 1 2 3 4 1 Marker hole 2 Square opening in rail Figure 10: Securing shelf brackets SHR-2265B 3 Screws with captive front mounting bracket, use the two flathead countersunk Phillips screws (10-32 x 0.25 in) provided. 52 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 53
a torque driver, torque the screws to 22 in/lb. Insert the Cage Nuts Read the following sections for instructions on inserting front and rear cage nuts in the rack. Insert the Front Cage Nuts in the Rack Use bracket, and insert the first of three cage nuts. Director 2/64 Installation Guide 53 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 54
sections, prepare to orient the switch in the rack as follows. WARNING: The Director 2/64 weighs approximately 115 pounds. Use proper handling and lifting equipment to reduce the possibility of injury contact with the outside surface of the mounting plate. 54 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 55
Installing and Configuring the Director 2/64 Figure 12: Aligning the switch in the rack 3. Loosely attach the rear angle bracket to the rack rail with the . b. Move to the front of the switch and secure each front mounting bracket with the three screws provided. Director 2/64 Installation Guide 55 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 56
an optional PDU in the rack. Hewlett-Packard ships two PDU power cords with the Director 2/64. WARNING: Hewlett-Packard power cords are provided for each director power supply. To prevent personal type, supplies the required voltage, and is properly grounded. 56 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 57
/e rack only, as shown in Figure 15: 1. Place the anti-tip feet (1), provided in the HP system/e and industry-standard 19-in rack mount kits on the front and rear of the rack base. 2. Secure the anti-tip feet (1) to the base of the rack (front and rear). Director 2/64 Installation Guide 57 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 58
Installing and Configuring the Director 2/64 3. Lower the rack feet (2) until they touch the floor. Figure 15: Mounting anti-tip feet for a HP system/e rack Install Mounting Bracket Hardware in the Rack Use these two rail tray brackets in the shipping carton. 58 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 59
Installing and Configuring the Director 2/64 Figure 16: Rail tray mounting location requirement 4. Position and attach both rear brackets, as shown in Figure 17: a. Locate the left and one on the right. c. Secure each rail tray bracket using one M5 Torx screw. Director 2/64 Installation Guide 59 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 60
Installing and Configuring the Director 2/64 3 1 Rear tray bracket 2 M5 screw with attached lock washer 3 HP rack 2 1 Figure 17: Attaching a rear rail tray bracket 18. 1 1 Tinnerman nut 2 Outer surface of HP rack 2 Figure 18: Installing a Tinnerman nut on the rack-front rail in U1 60 Director - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 61
Installing and Configuring the Director 2/64 6. Position the rail tray, as shown in Figure 19 and insert the tray into the rack from the front. Note and thread into the Tinnerman nuts installed on the rack uprights in step 5. b. Tighten both M5 Torx screws. Director 2/64 Installation Guide 61 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 62
Installing and Configuring the Director 2/64 Prepare the Front and Rear Rack Columns Use the following procedure to prepare the rack for installing a switch: 1. and 28th on the rack's back face. b. Slide a sheet metal nut (2) on each of the located holes. 62 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 63
Installing and Configuring the Director 2/64 Note: Two sheet metal nuts should be on each back column face (3). Figure 21: Preparing the rear rack columns mounting bracket (5) so that the bracket's angled side faces out and is on the upper part of switch side. Director 2/64 Installation Guide 63 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 64
Installing and Configuring the Director 2/64 3. Attach the bracket with 10-32, flat-head Phillips screws (4) using the two center threaded holes on the front two 10-32, flat-head Phillips screws. 8. Repeat step 6 and step 7 for the second rear mounting bracket. 64 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 65
the previous sections, install the switch in the rack as follows. WARNING: The Director 2/64 weighs approximately 115 pounds. Use proper handling and lifting equipment to reduce the possibility of injury the switch. Figure 23: Positioning the switch in the rack Director 2/64 Installation Guide 65 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 66
Installing and Configuring the Director 2/64 2. Mount the switch in the rack, as shown in Figure 24: a. On one side at the back of the switch, position the Front and Rear Rack Columns" on page 62. f. Tighten all screws. Figure 24: Securing the switch to the rack 66 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 67
optional PDU in the rack. Hewlett-Packard ships two PDU power cords with the Director 2/64. Figure 25: AC power connections WARNING: Hewlett-Packard power cords are provided for each screw (4) loosely in the hole on the inside face of the mounting bracket (5). Director 2/64 Installation Guide 67 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 68
Installing and Configuring the Director 2/64 Figure 26: Installing the sliding shelf brackets 6. Insert the shelf into the rack so that both rail rear slots (1) slide over the loose screws (2) on the inside face of each bracket, as shown in Figure 27. 68 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 69
Installing and Configuring the Director 2/64 Figure 27: Positioning the sliding shelf bracket on a rail rear slot 7. Make sure that the sliding shelf , tighten the screws that attach the sliding shelf rails to the mounting brackets, as shown in Figure 27 (2). Director 2/64 Installation Guide 69 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 70
Installing and Configuring the Director 2/64 Figure 28: Positioning the sliding shelf bracket at the rack front Recommended Cable Management Perform the following two positions on each side of the rack to maintain clearance for power supply access (3). 70 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 71
Installing and Configuring the Director 2/64 Figure 29: Recommended cable management Power-On Self Test Use port module (UPM) cards illuminate momentarily. ■ The green LED on each CTP2 card (active and backup) turns ON as the card is tested and UPM cards are tested. ■ Green LEDs associated with - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 72
the active CTP2 card, and green PWR OK LEDs on both power supplies remain ON. 4. If a POST error or other malfunction occurs, refer to the HP StorageWorks Director 2/64 Service Manual. 72 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 73
Installing and Configuring the Director 2/64 Configure Director Network Information Use the following sections to configure the director's network addressing items are required to perform this task: ■ A local workstation (desktop or notebook computer) with: Director 2/64 Installation Guide 73 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 74
Installing and Configuring the Director 2/64 - Microsoft Windows 98, Windows 2000, Windows XP, or Windows NT 4.0 operating system - RS-232 serial communication software (for example, ProComm Plus or -tip screwdriver may be required). See Figure 30 1. 74 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 75
Installing and Configuring the Director 2/64 1 Maintenance port 2 RS-232 port 3 Null Modem cable Figure 30: Connecting the null modem cable between the director other cable end to a 9-pin communication port (COM1 or COM2) at the rear of the local workstation. Director 2/64 Installation Guide 75 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 76
Installing and Configuring the Director 2/64 4. Choose Start > Programs > Accessories > Communications > HyperTerminal. The Connection Description dialog box displays, as shown in Figure click OK. The COMn Properties dialog box displays, as shown in Figure 33. 76 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 77
the Director 2/64 Figure 33: COMn Properties dialog box 7. Configure the Port Settings parameters as follows: ■ Bits per second: 115200 ■ Data bits: 8 ■ Parity: None ■ Stop bits: 1 ■ the IP Address, Subnet Mask, and Gateway Address fields are configurable. Director 2/64 Installation Guide 77 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 78
Installing and Configuring the Director 2/64 Figure 34: HyperTerminal dialog box 11. To change director network addresses, type the following at the C> prompt from the director and the maintenance terminal. Replace the protective cap over the maintenance port. 78 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 79
2 Ethernet hub or switch (customer supplied) 3 HAFM server (laptop or rack mount) 4 Director 2/64 Figure 35: LAN-connect the director 2. Connect the remaining end of each Ethernet cable to the LAN as LAN segment to an Internet connection and see Chapter 3. Director 2/64 Installation Guide 79 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 80
Installing and Configuring the Director 2/64 HAFM Server To run HAFM software, you must set up and configure the HAFM server. Refer to the HAFM server installation guide for instructions on: ■ Setting up the HAFM server. ■ Connecting the HAFM server to the LAN. ■ Configuring the network addressing - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 81
Installing and Configuring the Director 2/64 Verify Communication Between the Director and HAFM Server Follow these steps to been established, but the director is operating in degraded mode and requires service. This condition is typical if a port or redundant FRU fails. Go to step 2. - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 82
operation displays as degraded or a director failure is indicated (FRU alert symbols and a yellow triangle or red diamond at the alert panel), refer to the HP StorageWorks Director 2/64 Service Manual. 82 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 83
38: Hardware View page (with FRU failures) Set Director Date and Time The Director 2/64 Product Manager log entries are stamped with the date and time received from the director. down menu. The Configure Date and Time dialog box displays, as shown in Figure 39. Director 2/64 Installation Guide 83 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 84
Installing and Configuring the Director 2/64 3. Set director date and time manually, or set for periodic updates. For specific instructions, see the following sections: ■ Set Director Date and Time, page 83 time, and close the Configure Date and Time dialog box. 84 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 85
Installing and Configuring the Director 2/64 Synchronize Date and Time Use these steps to set the director to periodically synchronize date and time with . 4. Click OK. 5. Click Activate to enable synchronization and close the Configure Date and Time dialog box. Director 2/64 Installation Guide 85 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 86
Installing and Configuring the Director 2/64 Frequently Used HAFM Settings This section summarizes the most common HAFM tasks including: Note: For a complete reference on HAFM functionality, refer to the HP StorageWorks HA-Fabric Manager User Guide. ■ Set the Director Online, page 87 ■ Set the - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 87
. 5. Click OK. The Status table displays Online. Set the Director Offline When the Director 2/64 is set offline, all ports are set offline. The director transmits the offline sequence (OLS) to management workstations when obtaining data from managed directors. Director 2/64 Installation Guide 87 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 88
name should reflect the director's Ethernet network DNS host name. For example, if the DNS host name is SAN64.hp.com, the name entered in this dialog box is SAN64. b. Type a director description of 255 or fewer . OSI devices can communicate with each other if 88 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 89
Connection (FICON) channel. 4. Click Activate. 5. Set the director online. For instructions, see "Set the Director Online" on page 87. Configuring Switch Parameters Use the director is set offline. For instructions, see "Set the Director Offline" on page 87. Director 2/64 Installation Guide 89 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 90
. 2. After you change settings, click the Activate button. 3. Set the director online. For instructions, see "Set the Director Online" on page 87. Switch Parameters Configure the following parameters as is provided to enable this ID as an insistent domain ID. 90 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 91
Installing and Configuring the Director 2/64 Preferred Note: To change this value, domain ID assignment for multi-switch fabrics in the HP StorageWorks SAN High Availability Planning Guide for details. Insistent This option is not supported unless the SANtegrity binding feature is installed. Click - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 92
port. Consult with your HBA and storage device vendor to determine if enabling Domain RSCNs will cause problems with your HBA or storage products. Note that this option is required if Enterprise Fabric Mode . Click the check box to remove or add a checkmark. 92 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 93
if disabling this option (and thereby enabling RSCN transmission) will cause problems with your HBA or storage products. Director Speed At the Director . 1. Verify that the director is set offline. For instructions, see "Set the Director Offline" on page 87. . Director 2/64 Installation Guide 93 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 94
finished configuring the switch. 6. Set the director online. For instructions, see "Set the Director Online" on page 87. Fabric as required by your fabric. BB_Credit Configure the director to support buffer-to-buffer credit (BB_Credit) from 1 through 60. 94 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 95
Installing and Configuring the Director 2/64 Note: Set the same value for R_A_TOV on all directors and edge switches in a multi-switch fabric. If the one to Never Principal, the director with the Default setting and the lowest WWN becomes the principal director. Director 2/64 Installation Guide 95 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 96
Installing and Configuring the Director 2/64 At least one director in a multi-switch fabric needs refer to the section on principal switch selection for multi-switch fabrics in the HP StorageWorks SAN High Availability Planning Guide for details. For example, in the audit log, you may notice that the - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 97
the Director 2/64 Interop Mode Choose one of the following options: ■ Homogeneous Fabric-Choose this mode if the fabric contains only HP directors and on configuring this optional feature, refer to HP StorageWorks Director Product Manager User Guide. Configure Ports Perform this procedure to define - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 98
Installing and Configuring the Director 2/64 Figure 43: Configure Ports check boxes c. Click the 10-100 km check box to enable extended distance buffering for a port. A will allow selecting from a pop-up menu to set all ports to 1 Gb/sec, 2 Gb/sec, or Negotiate. 98 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 99
vertical scroll bar as necessary to display additional port information rows (up to 64 ports). 3. Click Activate to save the configuration information and close the dialog name. For instructions on configuring port addresses, refer to HP StorageWorks Director Product Manager User Guide for details. - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 100
name of the trap recipient (SNMP management workstation) in the associated Trap Recipient field. Use 64 or fewer alphanumeric characters. Hewlett-Packard recommends using the IP address. d. Type a decimal user to save the information and close the dialog box. 100 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 101
2/64 name of the SMTP server in the SMTP Server field. Use 64 or fewer alphanumeric characters. b. For the E-Mail Addresses fields, who should be informed of system events. Use 64 or fewer alphanumeric characters for each entry. 2. 64 icon. The Hardware View page for the selected director - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 102
Installing and Configuring the Director 2/64 5. Choose Maintenance > Enable E-Mail Notification. A check mark To learn more about configuring Call-Home features, refer to the HP StorageWorks HAFM server installation guide. Configure and Enable Ethernet Events Perform this procedure to configure and - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 103
Installing and Configuring the Director 2/64 ■ A yellow triangle that displays by the Threshold Alerts field in the Port Properties dialog box. ■ Detailed threshold alert data the alert, type of alert (Rx, Tx, or Rx or Tx), and alert state (inactive or active). Director 2/64 Installation Guide 103 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 104
48. Figure 48: New Threshold Alerts dialog box-first screen 3. Enter a name from one to 64 characters in length. All characters in the ISO Latin-1 character set, excluding control characters, are allowed. if the threshold set for receive throughput is reached 104 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 105
Installing and Configuring the Director 2/64 ■ Tx Throughput-An alert will occur if the threshold set for transmit throughput is reached. ■ Rx or which throughput is measured and threshold notifications can occur. The valid range is 5 minutes to 70,560 minutes. Director 2/64 Installation Guide 105 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 106
Installing and Configuring the Director 2/64 9. Click Next. A new screen displays for selecting ports for the alerts, as shown in Figure 50. Figure 50: Click Next. A final screen displays to provide a summary of your alert configuration, as shown in Figure 51. 106 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 107
Installing and Configuring the Director 2/64 Figure 51: New Threshold Alerts dialog box-summary screen 12. Click Finish. The Configure Threshold Alerts dialog is activated, as shown in Figure 52. Figure 52: Configure Threshold Alerts dialog box-alert activated Director 2/64 Installation Guide 107 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 108
Installing and Configuring the Director 2/64 Modify Alerts Use the following steps to modify an existing threshold alert configuration. 1. At the Hardware View page, the inactive state. If the alert is inactive, choose Activate to change to the active state. 108 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 109
Installing and Configuring the Director 2/64 Delete Alerts Use the following steps to delete existing threshold alerts. 1. At the Hardware View page, choose Send Test. Call-home and e-mail test messages are transmitted and an Information dialog box displays. Director 2/64 Installation Guide 109 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 110
Installing and Configuring the Director 2/64 5. Click OK. Verify that the intended server operating environment in case of hard drive failure. Refer to the HP StorageWorks HAFM server installation guide for instructions on backing up the HAFM configuration data. Once the HAFM configuration data - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 111
Installing and Configuring the Director 2/64 Enable Embedded Web Server Use the following steps to enable EWS: access the interface. For complete procedures on using EWS, refer to the HP StorageWorks Embedded Web Server User Guide. Enable Telnet Use the following steps to enable Telnet: 1. At the - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 112
Installing and Configuring the Director 2/64 . 1 Director 2/64 2 Fibre Channel cables 3 Workstation Figure 54: 16 maximum) and secure them as directed by the customer. 4. Set the director online. For instructions, see "Set the Director Online" on page 87. Connect the Director to a Fabric To - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 113
64 icon. The Hardware View page for the selected director displays. 6. Click the UPM card graphic supporting problem is indicated, consult the HP StorageWorks Director 2/64 Service Manual to isolate the problem. If no problems are indicated, installation is complete. Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 114
Installing and Configuring the Director 2/64 Figure 55: Port Properties dialog box Using HAFM from a Remote Location Use this system. - Hewlett-Packard HA PA-RISC processor with a 360 MHz or greater clock speed, using the HP-UX 11 or higher operating system. 114 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 115
least 15 MB available on the internal hard drive. ■ 32 MB or greater RAM. ■ Video card supporting 256 colors at 800 x 600 pixel resolution. ■ Ethernet network adapter. ■ Java-enabled Internet browser, database of any SNMPv2 compliant Network Management Station. Director 2/64 Installation Guide 115 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 116
2/64 Figure 56: HAFM remote client install 5. To install the HAFM remote client application, scroll down to the information that pertains to your platform and follow the instructions provided case-sensitive. 4. Click Login. The Products View page displays. 116 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 117
Manage Firmware Versions 3 3 The Director 2/64 internal operating code is downloaded from the HAFM server and stored on a CTP2 card. Up Version, page 122 ■ Download a Firmware Version to a Director, page 123 ■ Back Up the Director's Configuration, page 126 Director 2/64 Installation Guide 117 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 118
Manage Firmware Versions Determine a Director Firmware Version Use these steps to determine the Director 2/64 firmware version: 1. At the HAFM server, open the HAFM application. The Products View ■ YY is the release level ■ ZZ is the patch level 5. Click Close. 118 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 119
website. The uniform resource locator (URL) is http://www.hp.com/country/us/eng/support.html. b. Click on Firmware Downloads in left panel. HAFM server), transfer the firmware version file to the HAFM server by backup disk, CD-ROM, or other electronic means. 2. At the HAFM 64 Installation Guide 119 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 120
Version dialog box 6. Choose the desired firmware version file (downloaded in step 1) from the HAFM server backup drive, CD-ROM drive, or hard drive. Verify that the correct directory path and filename display in Firmware Library dialog box. 9. Click Close. 120 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 121
text that uniquely identifies the firmware version. The new description for the firmware version displays in the Director Firmware Library dialog box. 6. Click Close. Director 2/64 Installation Guide 121 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 122
click Delete. A confirmation dialog box displays. 5. Click OK. The selected firmware version is deleted from the Director Firmware Library dialog box. 6. Click Close. 122 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 123
operation. The new firmware version takes effect when control is passed from the active to the backup CTP2 card. Although director operation is not affected, name server, alias server, and login up. The Hardware View page for the selected director displays. Director 2/64 Installation Guide 123 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 124
61: Backup and Restore Configuration dialog box d. Click Backup. When the backup process finishes, the Backup Complete problem occurs and a corresponding message displays, refer to the HP StorageWorks Director 2/64 Service Manual for specific information on isolating the problem 64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 125
the dialog box to 100%. When the download reaches 100%, a "Send firmware complete" message displays. 8. Click Close to close the dialog box. 9. Click Close. Director 2/64 Installation Guide 125 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 126
director displays. 3. Choose Maintenance > Backup & Restore Configuration. The Backup and Restore Configuration dialog box displays, as shown in Figure 61. 4. Click Backup. When the backup process finishes, the Backup Complete dialog box displays. 5. Click OK. 126 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 127
132 ■ Japanese Notice, page 132 ■ Harmonics Conformance (Japan), page 133 ■ German Noise Declaration, page 133 ■ Laser Safety, page 134 ■ Declaration of Conformity, page 135 Director 2/64 Installation Guide 127 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 128
Hewlett-Packard Regulatory Model Number for this product is: RSVLB-0211 The HP StorageWorks Director 2/64 Regulatory Model Number can be found on the product label, along with with the marketing name or product number for your HP StorageWorks Director 2/64. 128 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 129
interference potential of the device as well as additional operating instructions for the user. The rating label on the device and used in accordance with the instructions, may cause harmful interference to radio and used in accordance with the instructions, may cause harmful interference to radio - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 130
that may cause undesired operation. For questions regarding your product, refer to http://www.hp.com. For questions regarding this FCC declaration, contact: Hewlett-Packard Company Product Regulations order to maintain compliance with FCC Rules and Regulations. 130 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 131
Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Director 2/64 Installation Guide 131 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 132
-3-3)-Voltage Fluctuations and Flicker ■ Also approved under UL 1950, 3rd Edition/CSA C22.2 No. 950-95, Safety of Information Technology Equipment Japanese Notice 132 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 133
Harmonics Conformance (Japan) Regulatory Compliance Notices German Noise Declaration Schalldruckpegel Lp = 68.8 dB(A) Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation) Nach ISO 7779:1988 / EN 27779:1991 (Typprüfung) Director 2/64 Installation Guide 133 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 134
as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated by a label on the plastic appears on the metal cover of the OLM housing: 134 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 135
Declaration of Conformity The Declaration of Conformity is shown below: Regulatory Compliance Notices Director 2/64 Installation Guide 135 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 136
Regulatory Compliance Notices 136 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 137
Technical Specifications B This appendix contains the following information: ■ Physical Dimensions, page 138 ■ Environmental Specifications, page 138 ■ Power Requirements, page 139 ■ Operating Tolerances, page 139 ■ Laser Information, page 140 B Director 2/64 Installation Guide 137 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 138
Specifications Table 7 lists environmental ranges for shipping, storing, and operating the HP StorageWorks Director 2/64. Table 7: Environmental Specifications Specification Shipping Weight 76.4 kg (168 lb) 8% to 80% 81°F (27°C) 10,000 ft (3,048 km) 138 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 139
Technical Specifications Power Requirements Table 8 lists Director 2/64 power requirements. Table 8: Power Requirements Specification Value Input voltage 100 to 120 non-recoverable errors tolerance Acoustical noise 6.9 Bels Inclination 10° maximum Director 2/64 Installation Guide 139 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 140
-mode: 1 m-10 Km 50/125 µm Multi-mode: 2 m-500 m 62.5/125 µm Multi-mode: 1 m-200 m Standard 100-SM-LL-L 100-SM-LL-L 100-M5-SN-I 140 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 141
Electrostatic Discharge C C This appendix contains the following information: ■ Precautions Against Electrostatic Discharge, page 142 ■ Grounding Methods, page 142 Director 2/64 Installation Guide 141 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 142
or dissipating floor mats. ■ Use conductive field service tools. ■ Use a portable field service kit with a folding static-dissipating work mat. If the suggested equipment for proper grounding, have a Hewlett-Packard authorized service provider install the part. Note: For more information on static - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 143
232 null modem cable 35 audience 12 authorized reseller, HP 17 B backing up director configuration file 126 bb_credit the director 2/64 27 configuration data, backing up 110 Director 2/64 Installation Guide Index Index configure software, introduction 22 dialog boxes configure fabric parameters 93 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 144
supplied 34 director 2/64 hardware components 27 installing 49 optional kits 37 director 2/64 firmware library dialog box 118 director 2/64 shipping carton items 46 configuring 110 features of the director 2/64 27 Federal Communications Commission (FCC) notice 129 fiber optic cleaning kit 36 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 145
2/64 Installation Guide Index Fibre Alliance MIB 23 hard drives, remote workstation 115 help, obtaining 17 Hewlett-Packard rack installation 57 hexagonal adapter 34 homogeneous fabric interop mode 97 hop counts 92 HP authorized reseller 17 storage website 17 technical support 17 HP - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 146
Index ISL, g_port 30 items director 2/64 shipping carton 46 L laser devices 134 information 135 laser transceivers 29 LEDs CTP2 cards 28 front bezel 28 power port module kit 37 M-Series rack mount kit 37 short-wave port module kits 37 OSI devices, communication 88 Director 2/64 Installation Guide - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 147
cable with wrist strap 36 fiber optic protective plug 35 Director 2/64 Installation Guide Index SANtegrity Binding features switch binding 97 SBAR assembly 32 segmentation causes of 26 serviceability features 22 set director date and time manually 84 setting, online state 87 shelf brackets 50, 58 - HP Surestore 64 | FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 148
support, HP 17 telnet, enabling 111 text symbols 13 tips for installing 49 tools supplied by service 64 firmware 21 FC fabric element MIB 23 firmware deleting 122 determining 118 modifying description 121 HP 14 web server, overview 21 websites HP storage 17 Windows operating systems, versions
installation
guide
hp
StorageWorks
director 2/64
Product Version:
FW V05.01.00-24/HAFM SW V07.01.00-09
Third Edition (June 2003)
Part Number:
AA–RSNGC–TE/958–000289–001
This guide provides procedures for setting up, configuring, and managing the HP StorageWorks
Director 2/64.