HP Surestore 64 FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide ( - Page 139
Power Requirements, Table 8: Power Requirements, Operating Tolerances, Table 9: Operating Tolerances
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Technical Specifications Power Requirements Table 8 lists Director 2/64 power requirements. Table 8: Power Requirements Specification Value Input voltage 100 to 120 or 200 to 240 VAC Input frequency 50/60 Hz Operating Tolerances Table 9 lists heating and cooling specifications, shock and vibration tolerances, acoustical noise, and inclination. Table 9: Operating Tolerances Specification Value Heat dissipation 16 UPM cards (maximum): 490W (1,672 BTU/hr) Cooling airflow clearances Right and left sides: 5.1 cm (2.0 in) Front and rear: 7.6 cm (3.0 in) Top and bottom: No clearance required Shock and vibration 60 Gs for 10 milliseconds without non-recoverable errors tolerance Acoustical noise 6.9 Bels Inclination 10° maximum Director 2/64 Installation Guide 139