Intel AFCSASRISER User Guide - Page 188

Rebuild automatically started on %s, Rebuild stopped on %s due to loss of cluster ownership

Page 188 highlights

Number 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 Type Info Info Critical Progress Info Info Warning Info Info Critical Info Warning Warning Progress Fatal Critical Fatal Info Info Info Critical Critical Progress Info Info Info Critical Fatal Fatal Info Fatal Info Warning Info Info Warning Info Info Critical Critical Critical Critical Critical Description State change on %s from %s to %s PD Clear aborted on %s PD Clear failed on %s (Error %02x) PD Clear progress on %s is %s PD Clear started on %s PD Clear completed on %s Error on %s (Error %02x) Format complete on %s Format started on %s Hot Spare SMART polling failed on %s (Error %02x) PD inserted: %s PD %s is not supported Patrol Read corrected medium error on %s at %lx Patrol Read progress on %s is %s Patrol Read found an uncorrectable medium error on %s at %lx Predictive failure: CDB: %s Patrol Read puncturing bad block on %s at %lx Rebuild aborted by user on %s Rebuild complete on %s Rebuild complete on %s Rebuild failed on %s due to source drive error Rebuild failed on %s due to target drive error Rebuild progress on %s is %s Rebuild resumed on %s Rebuild started on %s Rebuild automatically started on %s Rebuild stopped on %s due to loss of cluster ownership Reassign write operation failed on %s at %lx Unrecoverable medium error during rebuild on %s at %lx Corrected medium error during recovery on %s at %lx Unrecoverable medium error during recovery on %s at %lx PD removed: %s CDB: %s State change on %s from %s to %s State change by user on %s from %s to %s Redundant path to %s broken Redundant path to %s restored Dedicated Hot Spare PD %s no longer useful due to deleted array SAS topology error: Loop detected SAS topology error: Unaddressable device SAS topology error: Multiple ports to the same SAS address SAS topology error: Expander error SAS topology error: SMP timeout 176 Intel® RAID Software User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

176
Intel
®
RAID Software User’s Guide
81
Info
State change on %s from %s to %s
82
Info
PD Clear aborted on %s
83
Critical
PD Clear failed on %s (Error %02x)
84
Progress
PD Clear progress on %s is %s
85
Info
PD Clear started on %s
86
Info
PD Clear completed on %s
87
Warning
Error on %s (Error %02x)
88
Info
Format complete on %s
89
Info
Format started on %s
90
Critical
Hot Spare SMART polling failed on %s (Error %02x)
91
Info
PD inserted: %s
92
Warning
PD %s is not supported
93
Warning
Patrol Read corrected medium error on %s at %lx
94
Progress
Patrol Read progress on %s is %s
95
Fatal
Patrol Read found an uncorrectable medium error on %s at %lx
96
Critical
Predictive failure: CDB: %s
97
Fatal
Patrol Read puncturing bad block on %s at %lx
98
Info
Rebuild aborted by user on %s
99
Info
Rebuild complete on %s
100
Info
Rebuild complete on %s
101
Critical
Rebuild failed on %s due to source drive error
102
Critical
Rebuild failed on %s due to target drive error
103
Progress
Rebuild progress on %s is %s
104
Info
Rebuild resumed on %s
105
Info
Rebuild started on %s
106
Info
Rebuild automatically started on %s
107
Critical
Rebuild stopped on %s due to loss of cluster ownership
108
Fatal
Reassign write operation failed on %s at %lx
109
Fatal
Unrecoverable medium error during rebuild on %s at %lx
110
Info
Corrected medium error during recovery on %s at %lx
111
Fatal
Unrecoverable medium error during recovery on %s at %lx
112
Info
PD removed: %s
113
Warning
CDB: %s
114
Info
State change on %s from %s to %s
115
Info
State change by user on %s from %s to %s
116
Warning
Redundant path to %s broken
117
Info
Redundant path to %s restored
118
Info
Dedicated Hot Spare PD %s no longer useful due to deleted array
119
Critical
SAS topology error: Loop detected
120
Critical
SAS topology error: Unaddressable device
121
Critical
SAS topology error: Multiple ports to the same SAS address
122
Critical
SAS topology error: Expander error
123
Critical
SAS topology error: SMP timeout
Number
Type
Description