Intel AFCSASRISER User Guide - Page 82
Redundancy When Possible, Redundancy, Drive Security Method, Intel
View all Intel AFCSASRISER manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
4. Choose the configuration method and click Next. Figure 21. Intel® RAID BIOS Console 2 - Configuration Methods The following configuration methods options are provided: - Automatic Configuration There are two options in Redundancy. Redundancy When Possible or No Redundancy. Redundancy When Possible configures configures RAID 1 for systems with two drives or RAID 5 for systems with three or more drives, or RAID 6 for systems with three or more drives. All available physical drives are included in the virtual drive using all available capacity on the disks. No Redundancy configures all available drives as a RAID 0 virtual drive. There is a Drive Security Method option which is reserved to be enabled in future. Note: You must designate hot-spare drives before starting auto configuration using all available capacity on the disks. - Manual Configuration Allows you to configure the RAID mode. Note: Automatic Configuration cannot be used for RAID 10, 50, or 60 or with mixed SATA and SAS drives. 70 Intel® RAID Software User's Guide