Intel AFCSASRISER User Guide - Page 19
Disk Spanning, CPU Usage, pre-spanned arrays through RAID 1
View all Intel AFCSASRISER manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
• Strip size: One disk section • Stripe size: Total of one set of strips across all data disks, not including parity stripes • Stripe width: The number of disks involved Disk Spanning Disk spanning allows more than one array to be combined into a single virtual drive. The spanned arrays must have the same stripe size and must be contiguous. Spanning alone does not provide redundancy but RAID modes 10, 50, and 60 all have redundancy provided in their pre-spanned arrays through RAID 1, 5, or 6. Note: Spanning two contiguous RAID 0 drives does not produce a new RAID level or add fault tolerance. It does increase the size of the virtual volume and improves performance by doubling the number of spindles. Spanning for RAID 10, RAID 50, and RAID 60 requires two to eight arrays of RAID 1, 5, or 6 with the same stripe size and that always uses the entire drive. CPU Usage Resource allocation provides the user with the option to set the amount of compute cycles to devote to various tasks, including the rate of rebuilds, initialization, consistency checks, and patrol read. Setting resource to 100% gives total priority to the rebuild. Setting it at 0% means the rebuild will only occur if the system is not doing anything else. The default rebuild rate is 30%. Intel® RAID Software User's Guide 7