(3) Removing the power supply board and high voltage board 1. Remove the process unit (See page 5-4). 2. Remove the top cover/face-down output tray and left cover (See pages 5-5 and 5-6). 3. Remove three connectors 1 from the power supply board 2. 4. Remove eight screws 3. 5. Remove the power supply board 2 and high voltage board 4. (Note: The high voltage board 4 is directly connected to the bias board 5.) 6. Separate the high voltage board 4 from the power supply board 2. 3 2 1 5 4 3 Figure 5-2-13 Removing the power supply board and high voltage board FS-1050 5-14
FS-1050
5-14
(3) Removing the power supply board and high voltage board
1. Remove the process unit (See page 5-4).
2. Remove the top cover/face-down output tray and left cover (See pages 5-5 and 5-6).
3. Remove three connectors
1
from the power supply board
2
.
4. Remove eight screws
3
.
5. Remove the power supply board
2
and high voltage board
4
. (Note: The high voltage
board
4
is directly connected to the bias board
5
.)
6. Separate the high voltage board
4
from the power supply board
2
.
Figure 5-2-13 Removing the power supply board and high voltage board
3
2
1
4
5
3