Kyocera FS-1050 Service Manual - Page 103
Removing the bias board, Removing the bias board
View all Kyocera FS-1050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
(4) Removing the bias board 1. Remove the cassette and process unit (See page 5-4). 2. Remove the top cover/face-down output tray and left cover (See pages 5-5 and 5-6). 3. Remove the power supply board and high voltage board (See the previous page). 4. Stand the machine with the front side up. 5. Remove one connector 1 from the bias board 2. 6. Remove five screws 3. 7. Remove the bottom cover 4. 8. Remove the two connectors 5 from the bias board 2. 9. Remove the bias board 2. 5 3 1 2 4 3 Figure 5-2-14 Removing the bias board 5-15 FS-1050
FS-1050
5-15
(4) Removing the bias board
1. Remove the cassette and process unit (See page 5-4).
2. Remove the top cover/face-down output tray and left cover (See pages 5-5 and 5-6).
3. Remove the power supply board and high voltage board (See the previous page).
4. Stand the machine with the front side up.
5. Remove one connector
1
from the bias board
2
.
6. Remove five screws
3
.
7. Remove the bottom cover
4
.
8. Remove the two connectors
5
from the bias board
2
.
9. Remove the bias board
2
.
Figure 5-2-14 Removing the bias board
3
3
4
1
2
5