Kyocera FS-1050 Service Manual - Page 111

Removing the heater lamp, WARNING, CAUTION, Removing the heater lamp

Page 111 highlights

(2) Removing the heater lamp WARNING CAUTION The heater lamp is extremely hot immediately after the printer was running. Allow substantial period of time until it cools down. Also, the heater lamp is fragile: Handle it with great care. The heater lamps are fragile. Use extreme care when handling not to drop or break. Do not directly touch on the heater lamp. Finger prints on the heater lamp's outer surface can prevent proper fusing of toner on paper. When holding the heater lamp, hold the ceramic parts of heater lamp at both ends. When refitting the heater lamp, direct the short distance side from the projection in the middle of the lamp facing the machine's left side. 1. Remove and split the fuser unit (See page 5-20). 2. Remove all (four) separators (See previous page). 3. Remove one screw 1, release the tension of lamp A holder 2. 4. Remove the heater lamp 3 form the lamp B holder 4. 5. Remove the heater lamp 3 from the heat roller 5. 2 Machine right side 5 1 Long Projection Machine left side 3 Short 4 Figure 5-2-22 Removing the heater lamp 5-23 FS-1050

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177

FS-1050
5-23
(2) Removing the heater lamp
WARNING
The heater lamp is extremely hot immediately after the printer was running.
Allow substantial period of time until it cools down. Also, the heater lamp is
fragile: Handle it with great care.
CAUTION
The heater lamps are fragile. Use extreme care when handling not to drop or
break.
Do not directly touch on the heater lamp. Finger prints on the heater lamp’s outer
surface can prevent proper fusing of toner on paper. When holding the heater
lamp, hold the ceramic parts of heater lamp at both ends.
When refitting the heater lamp, direct the short distance side from the projection
in the middle of the lamp facing the machine’s left side.
1. Remove and split the fuser unit (See page 5-20).
2. Remove all (four) separators (See previous page).
3. Remove one screw
1
, release the tension of lamp A holder
2
.
4. Remove the heater lamp
3
form the lamp B holder
4
.
5. Remove the heater lamp
3
from the heat roller
5
.
Figure 5-2-22 Removing the heater lamp
5
3
4
1
2
Machine
left side
Machine
right side
Projection
Short
Long