Lexmark T620 Service Manual - Page 189
P1=OP P2=OP L=NL, Output Bin x
View all Lexmark T620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 189 highlights
4069-5XX/7XX TP=High-Capacity Stacker top position sensor P=High-Capacity Stacker pass thru sensor F=High-Capacity Stacker bin full sensor (lower par of dual sensor) NF=High-Capacity Stacker near full sensor (upper part of dual sensor) 5. Once the screen is displayed, manually actuate each of the sensors of the High-Capacity Stacker. When the sensor is closed CL displays, and when the sensor is open OP displays. 6. Select Return or Stop to exit the test. 5-Bin Mailbox Option 1. Select Output Bin tests from the menu. 2. Select Output Bin tests - Sensor Tests. 3. Select Sensor Tests for Output Bin x (x=number of the output option to be tested). 4. The following screen is displayed: Output Bin x P1=OP P2=OP L=NL P1=5-Bin Mailbox first pass thru sensor P2=5-Bin Mailbox second pass thru sensor L=EM, 5-Bin x empty L=NL, bin contains media, but the bin is NOT near full nor full L=NF, the bin is near full L=FL, the bin is full 5. Once the screen is displayed, manually actuate each of the sensors of the High-Capacity Stacker, except for the output level sensor. When the sensor is closed, CL displays, and when the sensor is open OP displays. 6. Select Return or Stop to exit the test. Diagnostic Aids 3-23