Lexmark T620 Service Manual - Page 241
Fuser Cover, Fuser Detack Fingers
View all Lexmark T620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 241 highlights
4069-5XX/7XX Fuser Cover 1. Remove the fuser assembly. 2. Note the thermistor cable routing and disconnect the cable. 3. Warning: Hold the left lamp bracket and carefully remove the two mounting screws. There is pressure against the other end of the lamp therefore care must be used when removing the lamp from the fuser. Grip the lamp by the ceramic end piece and remove it from the fuser assembly. Be careful not to touch the glass as skin oils and acids can reduce the life of the lamp. 4. Remove the right lamp bracket mounting screws (A). 5. Remove the left and right fuser cover mounting screws (B) and lift the cover from the fuser assembly. Fuser Detack Fingers 1. Remove the fuser assembly. 2. Remove the fuser cover assembly. 3. Remove the fuser detack housing assembly. Repair Information 4-31