Lexmark T620 Service Manual - Page 199
Print Tests, 5XX/7XX, Transfer, Print Contrast, Charge Roll
View all Lexmark T620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 199 highlights
4069-5XX/7XX lets the backup roll heat up and helps reduce curl in some environments. Transfer The transfer can be adjusted to: • LOW • MEDIUM • HIGH Print Contrast The print contrast setting controls the developer voltage offset. The print contrast can be adjusted to: • LOW • MEDIUM • HIGH Charge Roll The charge roll can be adjusted to: • LOW • MEDIUM • HIGH Print Tests The purpose of the diagnostic Print Tests is to verify that the printer can print on media from each of the installed input options. Each of the installed options is listed in the following order in the menu: Tray 1 Tray 2 (if installed) Tray 3 (if installed) Tray 4 (if installed) Tray 5 (if installed) Multipurpose Feeder (if installed) Diagnostic Aids 3-33
Diagnostic Aids
3-33
4069-5XX/7XX
lets the backup roll heat up and helps reduce curl in some
environments.
Transfer
The transfer can be adjusted to:
•
LOW
•
MEDIUM
•
HIGH
Print Contrast
The print contrast setting controls the developer voltage offset.
The print contrast can be adjusted to:
•
LOW
•
MEDIUM
•
HIGH
Charge Roll
The charge roll can be adjusted to:
•
LOW
•
MEDIUM
•
HIGH
Print Tests
The purpose of the diagnostic Print Tests is to verify that the printer
can print on media from each of the installed input options. Each of
the installed options is listed in the following order in the menu:
Tray 1
Tray 2 (if installed)
Tray 3 (if installed)
Tray 4 (if installed)
Tray 5 (if installed)
Multipurpose Feeder (if installed)