Lexmark T620 Service Manual - Page 239
Remove the LVPS., sensor cable and remove the toner sensor.
View all Lexmark T620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 239 highlights
4069-5XX/7XX Right Side Frame 1. Remove the right side cover. 2. Remove the LVPS. 3. Remove the multipurpose tray assembly. 4. Disconnect the auto compensator arm bias spring from the right side frame. 5. Remove the toner sensor mounting screw (A), disconnect the sensor cable and remove the toner sensor. 6. Remove the right side frame mounting screws (B) and remove the right side frame. CAUTION: Be sure the fuser assembly has cooled before working on any of the fuser FRUs. Repair Information 4-29
Repair Information
4-29
4069-5XX/7XX
Right Side Frame
1.
Remove the right side cover.
2.
Remove the LVPS.
3.
Remove the multipurpose tray assembly.
4.
Disconnect the auto compensator arm bias spring from the right
side frame.
5.
Remove the toner sensor mounting screw (A), disconnect the
sensor cable and remove the toner sensor.
6.
Remove the right side frame mounting screws (B) and remove
the right side frame.
CAUTION: Be sure the fuser assembly has cooled before