Pioneer VSX-1121-K Owner's Manual - Page 70

EQ Pro & S-Wave, STAND.WAVE Multi-Point

Page 70 highlights

10 The Advanced MCACC menu 2 Select the parameters you want to set. Use / to select the item, then use / to set. • Auto MCACC - The default is ALL (recommended), but you can limit the system calibration to only one setting (to save time) if you want.1 • EQ Type (only available when the Auto MCACC Menu above is EQ Pro & S-Wave) - This determines how the frequency balance is adjusted. After a single calibration is performed, each of the following three correction curves can be stored separately in the MCACC memory. SYMMETRY implements symmetric correction for each pair of left and right speakers to flatten the frequency-amplitude characteristics. ALL CH ADJ is a 'flat' setting where all the speakers are set individually so no special weighting is given to any one channel. FRONT ALIGN2 sets all speakers in accordance with the front speaker settings (no equalization is applied to the front left and right channels). • THX Speaker (only available when the Auto MCACC Menu above is ALL or Speaker Setting) - Select YES if you are using THX speakers (set all speakers to SMALL), otherwise leave it set to NO. • STAND.WAVE Multi-Point (only available when the Auto MCACC Menu above is EQ Pro & S-Wave) - In addition to measurements at the listening position, you can use two more reference points for which test tones will be analyzed for standing waves. This is useful if you want to get a balanced 'flat' calibration for several seating positions in your listening area. Place the microphone at the reference point indicated on-screen and note that the last microphone placement will be at your main listening position: 2nd reference point 1 3rd reference point 2 3 Main listening position 3 Connect the microphone to the MCACC SETUP MIC jack on the front panel. Make sure there are no obstacles between the speakers and the microphone. CONTROL ON / OFF MASTER VOLUME MCACC SETUP MIC iPod iPhone USB VIDEO CAMERA HDMI 5 Microphone Tripod If you have a tripod, use it to place the microphone so that it's about ear level at your normal listening position. If you do not have a tripod, use some other object to install the microphone.3 4 When you're finished setting the options, select START then press ENTER. 5 Follow the instructions on-screen. 6 Wait for the Auto MCACC Setup to finish outputting test tones. A progress report is displayed on-screen while the receiver outputs test tones to determine the speakers present in your setup. Try to be as quiet as possible while it's doing this.4 • With error messages (such as Too much ambient noise! or Check microphone) select RETRY after checking for ambient noise (see Problems when using the Auto MCACC Setup on page 37) and verifying the mic connection. If there doesn't seem to be a problem, you can simply select GO NEXT and continue. 7 If necessary, confirm the speaker configuration in the GUI screen. The configuration shown on-screen should reflect the actual speakers you have. Note 1 • When data measurement is taken (after selecting ALL or Keep SP System), the reverb characteristics data (both before- and aftercalibration) that this receiver had been storing will be overwritten. If you want to save the reverb characteristics data before measuring, connect a USB memory device to this receiver and transfer the data. • When measurement is taken of data other than SYMMETRY (after selecting ALL or Keep SP System), the data are not measured after the correction. If you will need to measure after correction data, take the measurement using the EQ Professional menu in the Manual MCACC setup (page 71). • The EQ Pro & S-Wave measurement is also taken when Keep SP System or EQ Pro & S-Wave is selected. See Acoustic Calibration EQ Professional on page 73 for more on this. • Either effect of Acoustic Calibration EQ Professional and Standing Wave can be switched on and off in the respective MCACC preset. For details, see Setting the Audio options on page 55. 2 If you selected ALL or Keep SP System as your Auto MCACC menu, you can specify the MCACC preset where you want to save the SYMMETRY, ALL CH ADJ and FRONT ALIGN settings. 3 It may not be possible to measure correctly if the microphone is placed on a table, sofa, etc. 4 Do not adjust the volume during the test tones. This may result in incorrect speaker settings. 70 En

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

The Advanced MCACC menu
10
70
En
2
Select the parameters you want to set.
Use
/
to select the item, then use
/
to set.
Auto MCACC
– The default is
ALL
(
r
ecommended),
but you can limit the system calib
r
ation to only one
setting (to save time) if you want.
1
EQ Type
(only available when the
Auto MCACC
Menu above is
EQ Pro & S-Wave
)
– This dete
r
mines
how the f
r
equency balance is adjusted.
Afte
r
a single calib
r
ation is
p
e
r
fo
r
med, each of the
following th
r
ee co
rr
ection cu
r
ves can be sto
r
ed
se
p
a
r
ately in the MCACC memo
r
y.
SYMMETRY
im
p
lements symmet
r
ic co
rr
ection fo
r
each
p
ai
r
of left
and
r
ight s
p
eake
r
s to flatten the f
r
equency-am
p
litude
cha
r
acte
r
istics.
ALL CH ADJ
is a ‘flat’ setting whe
r
e all
the s
p
eake
r
s a
r
e set individually so no s
p
ecial weighting
is given to any one channel.
FRONT ALIGN
2
sets all
s
p
eake
r
s in acco
r
dance with the f
r
ont s
p
eake
r
settings
(no equalization is a
pp
lied to the f
r
ont left and
r
ight
channels).
THX Speaker
(only available when the
Auto MCACC
Menu above is
ALL
or
Speaker Setting
)
– Select
YES
if you a
r
e using THX s
p
eake
r
s (set all s
p
eake
r
s to
SMALL
), othe
r
wise leave it set to
NO
.
STAND.WAVE Multi-Point
(only available when the
Auto MCACC
Menu above is
EQ Pro & S-Wave
)
– In
addition to measu
r
ements at the listening
p
osition,
you can use two mo
r
e
r
efe
r
ence
p
oints fo
r
which test
tones will be analyzed fo
r
standing waves. This is
useful if you want to get a balanced ‘flat’ calib
r
ation
fo
r
seve
r
al seating
p
ositions in you
r
listening a
r
ea.
Place the mic
r
o
p
hone at the
r
efe
r
ence
p
oint
indicated on-sc
r
een and note that
the last
microphone placement will be at your main listening
position:
3
Connect the microphone to the
MCACC SETUP MIC
jack on the front panel.
Make su
r
e the
r
e a
r
e no obstacles between the s
p
eake
r
s
and the mic
r
o
p
hone.
If you have a t
r
i
p
od, use it to
p
lace the mic
r
o
p
hone so that
it’s about ea
r
level at you
r
no
r
mal listening
p
osition. If you
do not have a t
r
i
p
od, use some othe
r
object to install the
mic
r
o
p
hone.
3
4
When you’re finished setting the options, select
START
then press
ENTER
.
5
Follow the instructions on-screen.
6
Wait for the Auto MCACC Setup to finish
outputting test tones.
A
pr
og
r
ess
r
e
p
o
r
t is dis
p
layed on-sc
r
een while the
r
eceive
r
out
p
uts test tones to dete
r
mine the s
p
eake
r
s
pr
esent in you
r
setu
p
. T
r
y to be as quiet as
p
ossible while
it’s doing this.
4
With e
rr
o
r
messages (such as
Too much ambient
noise!
o
r
Check microphone
) select
RETRY
afte
r
checking fo
r
ambient noise (see
Problems when
using the Auto MCACC Setup
on
p
age 37) and
ve
r
ifying the mic connection. If the
r
e doesn’t seem to
be a
pr
oblem, you can sim
p
ly select
GO NEXT
and
continue.
7
If necessary, confirm the speaker configuration in
the GUI screen.
The configu
r
ation shown on-sc
r
een should
r
eflect the
actual s
p
eake
r
s you have.
Note
1 • When data measu
r
ement is taken (afte
r
selecting
ALL
o
r
Keep SP System
), the
r
eve
r
b cha
r
acte
r
istics data (both befo
r
e- and afte
r
-
calib
r
ation) that this
r
eceive
r
had been sto
r
ing will be ove
r
w
r
itten. If you want to save the
r
eve
r
b cha
r
acte
r
istics data befo
r
e measu
r
ing,
connect a USB memo
r
y device to this
r
eceive
r
and t
r
ansfe
r
the data.
• When measu
r
ement is taken of data othe
r
than
SYMMETRY
(afte
r
selecting
ALL
o
r
Keep SP System
), the data a
r
e not measu
r
ed afte
r
the
co
rr
ection. If you will need to measu
r
e afte
r
co
rr
ection data, take the measu
r
ement using the EQ P
r
ofessional menu in the Manual MCACC
setu
p
(
p
age 71).
• The
EQ Pro & S-Wave
measu
r
ement is also taken when
Keep SP System
o
r
EQ Pro & S-Wave
is selected. See
Acoustic Calibration EQ
Professional
on
p
age 73 fo
r
mo
r
e on this.
• Eithe
r
effect of Acoustic Calib
r
ation EQ P
r
ofessional and Standing Wave can be switched on and off in the
r
es
p
ective MCACC
pr
eset. Fo
r
details, see
Setting the Audio options
on
p
age 55.
2 If you selected
ALL
o
r
Keep SP System
as you
r
Auto MCACC
menu, you can s
p
ecify the MCACC
pr
eset whe
r
e you want to save the
SYMMETRY
,
ALL CH ADJ
and
FRONT ALIGN
settings.
1
2
3
2nd
r
efe
r
ence
p
oint
3
r
d
r
efe
r
ence
p
oint
Main listening
p
osition
3 It may not be
p
ossible to measu
r
e co
rr
ectly if the mic
r
o
p
hone is
p
laced on a table, sofa, etc.
4 Do not adjust the volume du
r
ing the test tones. This may
r
esult in inco
rr
ect s
p
eake
r
settings.
MASTER
VOLUME
MCACC SETUP MIC
USB
iPod
iPhone
VIDEO
CAMERA
HDMI 5
CONTROL
ON
/
OFF
Mic
r
o
p
hone
T
r
i
p
od