Brother International HE-800B Instruction Manual - English - Page 66

Resetting the data (initialization), To carry out initialization]

Page 66 highlights

7. USING THE SEWING MACHINE (OPERATION PANEL: ADVANCED OPERATION) 7-3. Resetting the data (initialization) If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been made by means of memory switches, for instance. In such cases, it may be possible to restore normal operation by following the steps given below to initialize the memory setting data. 1 While pressing the RESET key, push the POWER switch (1) to the ON side. 4927M 4854M 2 Select the initialization level (2) from 1 to 3. The mode will switch to initialization mode. 4928M 4787M 3 [To carry out initialization] (Press for 2 seconds or more.) 4 [To exit initialization mode] Flashing Level 1 is selected as the default. * The settings that are reset (initialized) will vary depending on the initialization level selected. (Refer to the table below.) "OPERATING" will be displayed and initialization will start. * If you do not wish to carry out the initialization procedure, press the RESET key. 4794M 4917M 4857M Normal sewing machine operation will then be possible. Initialization level and settings that are reset or initialized. Program settings (Parameter) [P01-P50] Cycle programs [C1-C9] Program No. Cycle step no. Parameter No. Memory switch Production counter Lower thread counter Lower thread counter setting value Level 1 Default value Reset P01 S1 01 - - - - Operation panel mode - Cutter operation - Level 2 - - - - - Default value - - - - - Level 3 Default value Reset P01 S1 01 Default value 0 0 0 Program mode (PROGRAM indicator lights) Enabled (CUTTER ON indicator lights) 57 HE-800B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

7. USING THE SEWING MACHINE (OPERATION PANEL: ADVANCED OPERATION)
HE-800B
57
7-3. Resetting the data (initialization)
If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been made by
means of memory switches, for instance. In such cases, it may be possible to restore normal operation by following the steps
given below to initialize the memory setting data.
1
While pressing the RESET key, push the POWER switch (1) to the ON side.
The mode will switch to initialization
mode.
2
Select the initialization level (2) from 1 to 3.
Level 1 is selected as the default.
*
The settings that are reset (initialized) will vary
depending on the initialization level selected. (Refer to
the table below.)
3
[To carry out initialization]
“OPERATING” will be displayed and initialization will start.
*
If you do not wish to carry out the initialization procedure,
press the RESET key.
4
[To exit initialization mode]
Normal sewing machine operation will then be possible.
Initialization level and settings that are reset or initialized.
Level 1
Level 2
Level 3
Program settings (Parameter)
[P01–P50]
Default value
Default value
Cycle programs [C1–C9]
Reset
Reset
Program No.
P01
P01
Cycle step no.
S1
S1
Parameter No.
01
01
Memory switch
Default value
Default value
Production counter
0
Lower thread counter
0
Lower thread counter setting value
0
Operation panel mode
Program mode
(PROGRAM indicator lights)
Cutter operation
Enabled
(CUTTER ON indicator lights)
4927M
4854M
4928M
4787M
4794M
4917M
4857M
(Press for 2 seconds or more.)
Flashing