Brother International HE-800B Instruction Manual - English - Page 80

Table Of Error Codes, Danger

Page 80 highlights

10. TABLE OF ERROR CODES 10. TABLE OF ERROR CODES DANGER Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the control box cover. Touching areas where high voltages are present will result in serious injury from electric shocks. If a problem should occur with the sewing machine, the buzzer will sound and an error code and error message will appear in the display. Follow the remedy procedure to eliminate the cause of the problem. Flashing Switch-related errors 4933M Items with a "*" in the "Page" column should only be handled by a qualified technician. Code Cause Remedy E010 Stop switch was pressed during standby. Remove your finger from the stop switch (so that it is off). Page 1 E011 E012 E015 E016 E025 E035 E045 Press the RESET key to clear the error. Stop switch was pressed during sewing. * Press the key to move the needle and the work clamp so that you can continue sewing. 51 * If not continuing sewing, press the RESET key once more. 50 Stop switch was pressed while sewing machine was operating other than during sewing. Press the RESET key to clear the error. (Home position detection will be carried out automatically.) - The stop switch was still pressed when the power was turned on, or there is a problem with the stop switch connection. Turn off the power and check the connection of the stop switch connector P9 at the main P.C. board. 10* Problem with the stop switch connection. Turn off the power and check the connection of the stop switch connector P9 at the main P.C. board. 10* Treadle was still depressed to the 2nd step when the power was turned on, or treadle connection is faulty. (Start switch if a triple pedal is being used) Turn off the power, and then check that connector P12 on the motor P.C. board is properly connected. (Connector P15 on the main P.C. board if a triple pedal is being used) 74* Treadle was still depressed to the 1st step when the power was turned on, or treadle Turn off the power, and then check that connector P12 on connection is faulty. the motor P.C. board is properly connected. (Connector 74* (Work clamp switch if a triple pedal is P15 on the main P.C. board if a triple pedal is being used) being used) Treadle was still depressed backward when the power was turned on, or treadle Turn off the power, and then check that connector P12 on connection is faulty. the motor P.C. board is properly connected. (Connector 74* (Work clamp lifter switch if a triple pedal is P15 on the main P.C. board if a triple pedal is being used) being used) 71 HE-800B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

10. TABLE OF ERROR CODES
HE-800B
71
10. TABLE OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before
opening the control box cover. Touching areas where high voltages are present will result in serious injury from
electric shocks.
If a problem should occur with the sewing machine, the buzzer will sound and an error code and error message will appear in
the display.
Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Items with a “*” in the “Page” column should only be handled by a qualified technician.
Code
Cause
Remedy
Page
E010
Stop switch was pressed during standby.
Remove your finger from the stop switch (so that it is off).
1
E011
Stop switch was pressed during sewing.
Press the RESET key to clear the error.
* Press the
key to move the needle and the work
clamp so that you can continue sewing.
* If not continuing sewing, press the RESET key once
more.
51
50
E012
Stop switch was pressed while sewing
machine was operating other than during
sewing.
Press the RESET key to clear the error.
(Home position detection will be carried out automatically.)
E015
The stop switch was still pressed when
the power was turned on, or there is a
problem with the stop switch connection.
Turn off the power and check the connection of the stop
switch connector P9 at the main P.C. board.
10*
E016
Problem with the stop switch connection.
Turn off the power and check the connection of the stop
switch connector P9 at the main P.C. board.
10*
E025
Treadle was still depressed to the 2nd
step when the power was turned on, or
treadle connection is faulty.
(Start switch if a triple pedal is being used)
Turn off the power, and then check that connector P12 on
the motor P.C. board is properly connected. (Connector
P15 on the main P.C. board if a triple pedal is being used)
74*
E035
Treadle was still depressed to the 1st step
when the power was turned on, or treadle
connection is faulty.
(Work clamp switch if a triple pedal is
being used)
Turn off the power, and then check that connector P12 on
the motor P.C. board is properly connected. (Connector
P15 on the main P.C. board if a triple pedal is being used)
74*
E045
Treadle was still depressed backward
when the power was turned on, or treadle
connection is faulty.
(Work clamp lifter switch if a triple pedal is
being used)
Turn off the power, and then check that connector P12 on
the motor P.C. board is properly connected. (Connector
P15 on the main P.C. board if a triple pedal is being used)
74*
4933M
Flashing