UL - User-defined line type, WU - Select unit for pen width, LPRINT FT10, 1;PA4500, 5000;RR500
![]() |
View all Brother International HL-1070 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
2001/10/02 170 'Source 2 180 LPRINT "FT10,50;PA4000,5000;RR500,500;PA4500,5500;RR500,500;" 190 LPRINT "FT10,1;PA4500,5000;RR500,500;PA4000,5500;RR500,500;FT;" 200 ' 210 '( POLYGON ) 220 LPRINT "PA2000,1000;PM0;PDPA4000,1000,3000,3000;PM1;" 230 LPRINT "PA2500,1200,3500,1200,3000,2500;PM1;" 240 LPRINT "PA3000,800,3700,2500,2300,2500;PM1;" 250 LPRINT "PM2;FP;" 260 LPRINT CHR$(27); "%0A"; 270 LPRINT CHR$(27); "E"; 280 END UL - User-defined line type UL [ i ] [,g [...,]] [;] i ; unit type g : gap length • This command allows you to define line types which you can then subsequently select with the LT command. • i must be in the range 1-8. i identifies the line type that is to be defined. • The index parameter uses absolute values. • g (the gap length) alternately specifies pen up and pen down parts of the defined line type. A maximum of twenty line sections are permitted, the first of which is a pen down section. Numbers must be integers in the range 0~32767. These numbers are converted to percentages by the LT command. • Maximum definition for the gap of each line type is 20. • The sum of the gap parameters must be greater than 0. • Specifying an index number with no gap parameters sets the line type to the default pattern for that index number. • Using the command with no parameter sets all line types to the defaults. 10 '-User Defined Line Type20 WIDTH "LPT1:", 255 30 LPRINT CHR$(27); "E"; 40 LPRINT CHR$(27); "%0B"; 50 LPRINT "IN;SP1;;" 60 LPRINT "UL8,0,15,0,15,0,15,40,15;" 70 LPRINT "LT8,5;PA2000,2500;PDPA5000,2500;PU;" 80 LPRINT "UL4,40,15,0,15,0,15,40,15,0,15;" 90 LPRINT "LT4,10;PA2000,3000;PDPA5000,3000;PU;" 100 LPRINT "UL1,40,40,40,40,40;" 110 LPRINT "LT1,10;PA2000,3500;PDPA5000,3500;PU;" 120 LPRINT CHR$(27); "%0A"; 130 LPRINT CHR$(27); "E"; 140 END WU - Select unit for pen width WU [ t ] [;] t ; unit type • This command specifies the pen width unit. It applies to all pens. • t must be either 0 or 1. • If t is 0 the pen width parameter which accompanies subsequent PW commands will be treated as a reading in millimeters. • If t is 1 the pen width parameter which accompanies subsequent PW commands will be treated as percentage of the distance between the scaling points P1 and P2. The default width is 0.1% of the diagonal distance from P1 to P2. CHAPTER 4 HP-GL/2 - 38
![](/manual_guide/products/brother-international-hl1070-technical-reference-329cc8c/186.png)