2001/10/02 7.7. USTATUSOFF Command The @PJL USTATUSOFF command makes all unsolicited status reporting inactive. Syntax @PJL USTATUSOFF [] Parameters There are no parameters for this command. Example %-12345X@PJL @PJL USTATUSOFF @PJL USTATUS DEVICE = ON %-12345X 7.8. JOB Recovery You can recover a failed job with the combination of JOB and EOJ commands and the USTATUS PAGE command. JOB/EOJ commands inform the printer of the beginning and ending of each job and the USTATUS PAGE command informs the application of completion of printing of each page of a job. When the spooler finds a job failure, it can recover the failed job. It can send the JOB command with the START option. The START page should be set to the last printed page, which can be found by the USTATUS PAGE command. CHAPTER 5 PJL - 54