Canon imageFORMULA ScanFront 400 Instruction Manual - Page 91
Background smoothing, Bleed-through reduction, Remove shadow, Erase Dot, images on both sides.
![]() |
View all Canon imageFORMULA ScanFront 400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Detects skewing that occurs in documents during document transport and in scanned images and corrects it. Hint The deskew function may not operate properly in the following cases. In such cases, disable the deskew function. (Even in cases other than the following, skewing in documents may not be properly corrected and portions may be cut off in the scanned image depending on the document.) • When scanning documents with dark edges • When scanning glossy or reflective documents Background smoothing Processes the scanned image so that the background is smooth. Bleed-through reduction Chapter 4 Operating Procedures page, such as when scanning thin documents with text or images on both sides. IMPORTANT Bleed-through reduction cannot be set when the [Text enhance] mode is selected. Hint When using bleed-through reduction, adjust the bleed-through reduction level to match the type of document. Remove shadow Removes shadows at the top and bottom of scanned images automatically. Erase Dot Automatically remove isolated 3 × 3 dot black spots on white backgrounds (or isolated 3 × 3 dot white spots on black backgrounds). Erase Notch Remove protrusions (i.e., notches) in contours in scanned images. Eliminates bleed-through images, in which images on the reverse side of a scanned document appear on the scanned 91
![](/manual_guide/products/canon-imageformula-scanfront-400-instruction-manual-87e22fe/91.png)